Evidence map›Paper›PMID 36772975›Full record

ArticleProceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine2023

Low dose CT-based spatial analysis (CTSA) to measure implant migration after ceramic hip resurfacing arthroplasty (HRA): A phantom study.

Susannah G Clarke, Kartik Logishetty, Camilla Halewood, Justin P Cobb

Abstract read
In one paragraph

Article in Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Precision, Accuracy, and Observer Reliability of Computed Tomography-Based Radiostereometric Analysis in Measuring Femoral Stem Migration In Vitro.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
    Article
  5. Inducible displacement of cementless total knee arthroplasty components with conventional and weight-bearing CT-based radiostereometric analysis.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Susannah G ClarkeMSk Lab, Imperial College London, London, UK.ORCID 0000-0003-0169-3438
Kartik LogishettyMSk Lab, Imperial College London, London, UK.ORCID 0000-0003-1332-5042
Camilla HalewoodEmbody Orthopaedic Limited, London.
Justin P CobbMSk Lab, Imperial College London, London, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Implant migration is a predictor of arthroplasty survivorship. It is crucial to monitor the migration of novel hip prostheses within premarket clinical investigations. RSA is the gold standard method, but requires calibrated radiographs using specialised equipment. A commercial computed tomography micromotion analysis solution is a promising alternative but is not yet available for use with monobloc ceramic implants. This study aimed to develop and validate a CT-based spatial analysis (CTSA) method for use with ceramic implants. A phantom study was undertaken to assess accuracy and precision. A ceramic hip resurfacing arthroplasty (HRA) and 20 tantalum beads were implanted into a synthetic hip model and mounted onto a 6-degree of freedom motion stage. The hip was repeatedly scanned with a low dose CT protocol, with imposed micromovements. Data were interrogated using a semiautomated technique. The effective radiation dose for each scan was estimated to be 0.25 mSv. For the head implant, precision ranged between 0.11 and 0.28 mm for translations and 0.34°-0.42° for rotations. For the cup implant, precision ranged between 0.08 and 0.11 mm and 0.19° and 0.42°. For the head, accuracy ranged between 0.04 and 0.18 mm for translations and 0.28°-0.46° for rotations. For the cup, accuracy ranged between 0.04 and 0.08 mm and 0.17° and 0.43°. This in vitro study demonstrates that low dose CTSA of a ceramic HRA is similar in accuracy to RSA. CT is ubiquitous, and this method may be an alternative to RSA to measure prosthesis migration.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisPhantoms, ImagingTomography, X-Ray ComputedBiomedical devicescomputed tomography (CT) analysiship prothesesimaging (medical)implant migrationimplants/prostheticsphotogrammetry/stereo photogrammetry (medical)

Identifiers

PMID36772975
PMCPMC10052406

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.