ArticleSensors (Basel, Switzerland)2023
End-Point Position Estimation of a Soft Continuum Manipulator Using Embedded Linear Magnetic Encoders.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- A Positioning System Design Based on Tunnel Magnetoresistance Sensors for Rapid Zoom Optical Lens.Sensors (Basel, Switzerland) · 2025Article
- Sensing of Continuum Robots: A Review.Sensors (Basel, Switzerland) · 2024Review
- Design and Experimental Validation of a 3D-Printed Embedded-Sensing Continuum Robot for Neurosurgery.Micromachines · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
Soft continuum robots are compliant mechanisms that rely on a deformable structure in order to achieve a desired posture. One of the challenges in designing and controlling this type of robot is to obtain the necessary proprioceptive information without resorting to external sensors, like cameras or 3D positioning devices. This requires a reliable and repeatable sensor that can be embedded in the highly deformable structure, distributed along its length, without imposing a significant change to the overall stiffness. This paper presents design considerations and practical results of estimating the tip position of a soft continuum manipulator module using embedded linear magnetic encoders. Three flexible scales with incremental tracks and a magnetic pole pitch of 2 mm are embedded in the robot structure as passive tendons, and six pairs of Hall effect linear sensors are used to measure the relative displacement between points along the outer surface of the structure. The curvature and tip position are then estimated from these measurements. Results are compared with the ground truth measurement of the tip position provided by a commercial optical tracker system. Average error estimates lower than 2.0 mm, with 8.7 mm peak value, were obtained for a robot module with a motion span of approximately 100 mm.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.