Evidence map›Paper›PMID 36772656›Full record

ArticleSensors (Basel, Switzerland)2023

Linear and Non-Linear Heart Rate Variability Indexes from Heart-Induced Mechanical Signals Recorded with a Skin-Interfaced IMU.

Čukić Milena, Chiara Romano, Francesca De Tommasi, Massimiliano Carassiti, Domenico Formica, Emiliano Schena, Carlo Massaroni

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Čukić MilenaEmpa Materials Science and Technology, Biomimetic Membranes and Textiles, 9014 St. Gallen, Switzerland.ORCID 0000-0002-9162-987X
Chiara RomanoUnit of Measurements and Biomedical Instrumentation, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy.ORCID 0000-0003-3525-0213
Francesca De TommasiUnit of Measurements and Biomedical Instrumentation, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy.ORCID 0000-0003-3575-6038
Massimiliano CarassitiUnit of Anesthesia, Intensive Care and Pain Management, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy.ORCID 0000-0001-9882-5219
Domenico FormicaSchool of Engineering, Newcastle University, Newcastle upon Tyne NE1 7RU, UK.
Emiliano SchenaUnit of Measurements and Biomedical Instrumentation, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy.ORCID 0000-0002-9696-1265
Carlo MassaroniUnit of Measurements and Biomedical Instrumentation, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy.ORCID 0000-0002-3090-5623

Funding

Strategic Projects 2019- POR FESR Lazio 2014-2020 586 SMILE project A0320-2019- 28107
6 · The paper itself

Abstract

Heart rate variability (HRV) indexes are becoming useful in various applications, from better diagnosis and prevention of diseases to predicting stress levels. Typically, HRV indexes are retrieved from the heart's electrical activity collected with an electrocardiographic signal (ECG). Heart-induced mechanical signals recorded from the body's surface can be utilized to record the mechanical activity of the heart and, in turn, extract HRV indexes from interbeat intervals (IBIs). Among others, accelerometers and gyroscopes can be used to register IBIs from precordial accelerations and chest wall angular velocities. However, unlike electrical signals, the morphology of mechanical ones is strongly affected by body posture. In this paper, we investigated the feasibility of estimating the most common linear and non-linear HRV indexes from accelerometer and gyroscope data collected with a wearable skin-interfaced Inertial Measurement Unit (IMU) positioned at the xiphoid level. Data were collected from 21 healthy volunteers assuming two common postures (i.e., seated and lying). Results show that using the gyroscope signal in the lying posture allows accurate results in estimating IBIs, thus allowing extracting of linear and non-linear HRV parameters that are not statistically significantly different from those extracted from reference ECG.

Indexed as

HeartThoracic WallElectrocardiographyHeart RateHumansPosturegyrocardiographyheart rateheart rate variabilityHRVinertial unitslinear HRVnon-linear HRVseismocardiography

Identifiers

PMID36772656
PMCPMC9920051

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked