ArticleSensors (Basel, Switzerland)2023
A Joint-Parameter Estimation and Bayesian Reconstruction Approach to Low-Dose CT.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Most penalized maximum likelihood methods for tomographic image reconstruction based on Bayes' law include a freely adjustable hyperparameter to balance the data fidelity term and the prior/penalty term for a specific noise-resolution tradeoff. The hyperparameter is determined empirically via a trial-and-error fashion in many applications, which then selects the optimal result from multiple iterative reconstructions. These penalized methods are not only time-consuming by their iterative nature, but also require manual adjustment. This study aims to investigate a theory-based strategy for Bayesian image reconstruction without a freely adjustable hyperparameter, to substantially save time and computational resources. The Bayesian image reconstruction problem is formulated by two probability density functions (PDFs), one for the data fidelity term and the other for the prior term. When formulating these PDFs, we introduce two parameters. While these two parameters ensure the PDFs completely describe the data and prior terms, they cannot be determined by the acquired data; thus, they are called complete but unobservable parameters. Estimating these two parameters becomes possible under the conditional expectation and maximization for the image reconstruction, given the acquired data and the PDFs. This leads to an iterative algorithm, which jointly estimates the two parameters and computes the to-be reconstructed image by maximizing a posteriori probability, denoted as joint-parameter-Bayes. In addition to the theoretical formulation, comprehensive simulation experiments are performed to analyze the stopping criterion of the iterative joint-parameter-Bayes method. Finally, given the data, an optimal reconstruction is obtained without any freely adjustable hyperparameter by satisfying the PDF condition for both the data likelihood and the prior probability, and by satisfying the stopping criterion. Moreover, the stability of joint-parameter-Bayes is investigated through factors such as initialization, the PDF specification, and renormalization in an iterative manner. Both phantom simulation and clinical patient data results show that joint-parameter-Bayes can provide comparable reconstructed image quality compared to the conventional methods, but with much less reconstruction time. To see the response of the algorithm to different types of noise, three common noise models are introduced to the simulation data, including white Gaussian noise to post-log sinogram data, Poisson-like signal-dependent noise to post-log sinogram data and Poisson noise to the pre-log transmission data. The experimental outcomes of the white Gaussian noise reveal that the two parameters estimated by the joint-parameter-Bayes method agree well with simulations. It is observed that the parameter introduced to satisfy the prior's PDF is more sensitive to stopping the iteration process for all three noise models. A stability investigation showed that the initial image by filtered back projection is very robust. Clinical patient data demonstrated the effectiveness of the proposed joint-parameter-Bayes and stopping criterion.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.