Evidence map›Paper›PMID 36772409›Full record

ArticleSensors (Basel, Switzerland)2023

Reliability of Mental Workload Index Assessed by EEG with Different Electrode Configurations and Signal Pre-Processing Pipelines.

Alfonso Mastropietro, Ileana Pirovano, Alessio Marciano, Simone Porcelli, Giovanna Rizzo

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Alfonso MastropietroInstitute of Biomedical Technologies, National Research Council, Via Fratelli Cervi 93, 20054 Segrate, Italy.ORCID 0000-0003-3358-7111
Ileana PirovanoInstitute of Biomedical Technologies, National Research Council, Via Fratelli Cervi 93, 20054 Segrate, Italy.ORCID 0000-0003-4905-3990
Alessio MarcianoDepartment of Molecular Medicine, University of Pavia, Via Forlanini 6, 27100 Pavia, Italy.
Simone PorcelliDepartment of Molecular Medicine, University of Pavia, Via Forlanini 6, 27100 Pavia, Italy.
Giovanna RizzoInstitute of Biomedical Technologies, National Research Council, Via Fratelli Cervi 93, 20054 Segrate, Italy.ORCID 0000-0002-6341-1304

Funding

Istituto Nazionale per l'Assicurazione Contro gli Infortuni sul Lavoro PR19-SV-P1 "Rip@rto" - Simulatore di guida per assistere operatori nella valutazione delle capacità di guida dell'utente e nella scelta degli ausili di cui dotare l'automobile
6 · The paper itself

Abstract

BACKGROUND AND

objectiveMental workload (MWL) is a relevant construct involved in all cognitively demanding activities, and its assessment is an important goal in many research fields. This paper aims at evaluating the reproducibility and sensitivity of MWL assessment from EEG signals considering the effects of different electrode configurations and pre-processing pipelines (PPPs).

methodsThirteen young healthy adults were enrolled and were asked to perform 45 min of Simon's task to elicit a cognitive demand. EEG data were collected using a 32-channel system with different electrode configurations (fronto-parietal; Fz and Pz; Cz) and analyzed using different PPPs, from the simplest bandpass filtering to the combination of filtering, Artifact Subspace Reconstruction (ASR) and Independent Component Analysis (ICA). The reproducibility of MWL indexes estimation and the sensitivity of their changes were assessed using Intraclass Correlation Coefficient and statistical analysis.

resultsMWL assessed with different PPPs showed reliability ranging from good to very good in most of the electrode configurations (average consistency > 0.87 and average absolute agreement > 0.92). Larger fronto-parietal electrode configurations, albeit being more affected by the choice of PPPs, provide better sensitivity in the detection of MWL changes if compared to a single-electrode configuration (18 vs. 10 statistically significant differences detected, respectively).

conclusionsThe most complex PPPs have been proven to ensure good reliability (>0.90) and sensitivity in all experimental conditions. In conclusion, we propose to use at least a two-electrode configuration (Fz and Pz) and complex PPPs including at least the ICA algorithm (even better including ASR) to mitigate artifacts and obtain reliable and sensitive MWL assessment during cognitive tasks.

Indexed as

ElectroencephalographyWorkloadAdultElectrodesHumansReproducibility of ResultsSignal Processing, Computer-Assistedcognitive performanceEEGmental workloadreliabilitysignal processingSimon task

Identifiers

PMID36772409
PMCPMC9920504

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.