Temperature and Humidity Stability of Fibre Optic Sensor Cables for High Resolution Measurements.

Marcus Maier, Cedric Kechavarzi, Xiaomin Xu, Janet M Lees

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Marcus MaierDepartment of Engineering, University of Cambridge, Cambridge CB3 0FA, UK.ORCID 0000-0003-0112-8949
Cedric KechavarziCentre for Smart Infrastructure and Construction, University of Cambridge, Cambridge CB3 0FA, UK.
Xiaomin XuCentre for Smart Infrastructure and Construction, University of Cambridge, Cambridge CB3 0FA, UK.
Janet M LeesDepartment of Engineering, University of Cambridge, Cambridge CB3 0FA, UK.ORCID 0000-0002-8295-8321

Funding

UK Engineering and Physical Sciences Research Council EP/N017668/1UK Engineering and Physical Sciences Research Council EP/N021614/1
6 · The paper itself

Abstract

Fibre optic sensors offer a means for the real-time continuous measurement of temperature or strain in concrete structures. Backscattered light along a fibre optic sensing (FOS) cable is interrogated to record a frequency shift and this shift is typically translated into a physical parameter such as strain or temperature using a calibration factor. However, when the measured frequency shift is a response to a combination of mechanical, thermal or hygral (humidity) loadings it is difficult to decouple individual influences. This presents a challenge in complex materials such as concrete where the strain, temperature and moisture levels change concurrently during the fresh and hardened states. Furthermore, depending on the application, both short- and longer-term measurements are required. As such, not only is the influence of these physical factors of interest but also the time and spatial stability of the measured frequency, which is highly dependent on the FOS cable composition. To investigate this aspect, fibre optic cables commonly used for strain (three tight-buffered cables) or temperature (two loose-buffered cables) measurement were considered. The cables were subjected to mechanical or environmental exposure and interrogated using a high-resolution optical backscatter reflectometer. The exposure regimes included three temperature cycles with sustained steps from 10 °C to 60 °C and back to 10 °C and an increasing and decreasing humidity cycle with steps between 30 to 90% relH. These ranges were selected to be indicative of typical environments for concrete. The results showed that the calibration factors back-calculated from increasing and decreasing temperature or humidity cycles differed. The third temperature cycle results were found to exhibit the smallest differences between heating and cooling suggesting that temperature pre-conditioning prior to installation could be advantageous. For all the cables, a drift in the readings was observed over the duration (2.5 h for temperature and 30 h for moisture) of the sustained steps. The magnitude of the drift depended on the cable type and exposure condition. In addition, local frequency fluctuations along the cable were observed which would need to be taken into account if only a single point along the cable length was used for analysis. The obtained results highlight the importance of the cable selection to maximise the FOS measurement fidelity for a given parameter of interest.

Indexed as

calibrationconcretedistributed fibre optical sensorshumiditystraintemperature

Identifiers

PMID36772336
PMCPMC9919857

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.