Evidence map›Paper›PMID 36772280›Full record

ArticleSensors (Basel, Switzerland)2023

Optimizing Resources and Increasing the Coverage of Internet-of-Things (IoT) Networks: An Approach Based on LoRaWAN.

Matheus Araujo Gava, Helder Roberto Oliveira Rocha, Menno Jan Faber, Marcelo Eduardo Vieira Segatto, Heinrich Wörtche, Jair Adriano Lima Silva

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Matheus Araujo GavaDepartment of Electrical Engineering, Federal University of Espírito Santo, Av. Fernando Ferrari, 514, Vitoria 29075-910, ES, Brazil.ORCID 0000-0002-5717-4605
Helder Roberto Oliveira RochaDepartment of Electrical Engineering, Federal University of Espírito Santo, Av. Fernando Ferrari, 514, Vitoria 29075-910, ES, Brazil.ORCID 0000-0001-6215-664X
Menno Jan FaberDepartment of Electrical Engineering, Federal University of Espírito Santo, Av. Fernando Ferrari, 514, Vitoria 29075-910, ES, Brazil.
Marcelo Eduardo Vieira SegattoDepartment of Electrical Engineering, Federal University of Espírito Santo, Av. Fernando Ferrari, 514, Vitoria 29075-910, ES, Brazil.
Heinrich WörtcheSensors and Smart Systems Group, Institute of Engineering, Hanze University of Applied Sciences, 9747 AS Groningen, The Netherlands.ORCID 0000-0003-2263-0495
Jair Adriano Lima SilvaDepartment of Electrical Engineering, Federal University of Espírito Santo, Av. Fernando Ferrari, 514, Vitoria 29075-910, ES, Brazil.ORCID 0000-0003-2567-184X

Funding

Coordenação de Aperfeicoamento de Pessoal de Nível Superior CAPES-PRINT-88881.311735/2018-01Fundação de Amparo à Pesquisa do Espírito Santo FAPES-2021-WMR44, FAPES NEsT-5G- 396 84343540, 1017/2022-P:2022-BWBR2Hanze University of Applied Sciences Research Centre 398 Biobased EconomyNational Council for Scientific and Technological Development CNPq 309737/2021-4, 309490/2021-9, and 158780/2019- 397 1
6 · The paper itself

Abstract

A resource optimization methodology is proposed for application in long range wide area networks (LoRaWANs). Using variable neighborhood search (VNS) and a minimum-cost spanning tree algorithm, it reduces the implementation and the maintenance costs of such low power networks. Performance evaluations were conducted in LoRaWANs with LoRa repeaters to increase coverage, in scenario where the number and the location of the repeaters are determined by the VNS metaheuristic. Parameters such as spread factor (SF), bandwidth and transmission power were adjusted to minimize the network's total energy per useful bit (Ebit) and the total data collection time. The importance of the SF in the trade-off between (Ebit) and time on-air is evaluated, considering a device scaling factor. Simulation results, obtained after model adjustments with experimental data, show that, in networks with few associated devices, there is a preference for small values of SF aiming at reduction of Ebit. The usage of large SF's becomes relevant when reach extensions are required. The results also demonstrate that, for networks with high number of nodes, the scaling of devices over time become relevant in the fitness function, forcing an equal distribution of time slots per SF to avoid discrepancies in the time data collection.

Indexed as

long-range wide area networkminimum spanning treescalabilityvariable neighborhood search

Identifiers

PMID36772280
PMCPMC9921952

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.