Evidence map›Paper›PMID 36772271›Full record

ArticleSensors (Basel, Switzerland)2023

CMOS Detector Staggered Array Module for Sub-Terahertz Imaging on Conveyor Belt System.

Moon-Jeong Lee, Ha-Neul Lee, Ga-Eun Lee, Seong-Tae Han, Dong-Woo Kang, Jong-Ryul Yang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Advanced Field-Effect Sensors.Sensors (Basel, Switzerland) · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Moon-Jeong LeeDepartment of Electronic Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea.
Ha-Neul LeeDepartment of Electronic Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea.ORCID 0000-0002-8717-8455
Ga-Eun LeeDepartment of Electronic Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea.
Seong-Tae HanElectrophysics Research Center, Korea Electrotechnology Research Institute, Changwon 51543, Republic of Korea.ORCID 0000-0002-7032-2457
Dong-Woo KangAI Compact SoC Research Section, Electronics and Telecommunications Research Institute, Daejeon 34129, Republic of Korea.ORCID 0000-0003-4091-3253
Jong-Ryul YangDepartment of Electronic Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea.ORCID 0000-0003-4939-3274

Funding

Electronics and Telecommunications Research Institute 2019-0-00008Institute of Information & Communication Technology Planning & Evaluation 2018-0-00711
6 · The paper itself

Abstract

A complementary metal-oxide-semiconductor (CMOS) detector array is proposed to improve the sub-terahertz imaging resolution for objects in the conveyor belt system. The image resolution is limited to the implemented configuration, such as the wide spacing in the detector array, the high conveyor belt speed, and the slow response of the signal conditioning block. The proposed array can improve the image resolution in the direction perpendicular to the movement of the belt, which is determined by the size and interval of the detector pixel, by configuring the array into two replaceable columns located at the misaligned horizontal positions. Replaceable detector unit pixels are individually attached to the motherboard after measuring and evaluating the detection performance to construct the proposed array. The intensities of 32 detector pixels placed under the conveyor belt with a width of 160 mm were initially calibrated in every image, including the beam pattern of 0.2 THz signals generated from the gyrotron. The image resolution of the perpendicular direction obtained from the proposed array was measured to be approximately 5 mm at a conveyor belt speed of 16 mm/s, demonstrating a 200% improvement in resolution compared to the conventional linear array under the same conditions.

Indexed as

array layoutCMOS detectorconveyor belthigh-resolutionreplaceable arraysub-terahertz imaging

Identifiers

PMID36772271
PMCPMC9920622

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.