Evidence map›Paper›PMID 36770492›Full record

ArticleNanomaterials (Basel, Switzerland)2023

Study on the Simulation of Biosensors Based on Stacked Source Trench Gate TFET.

Chen Chong, Hongxia Liu, Shougang Du, Shulong Wang, Hao Zhang

Abstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Chen ChongKey Laboratory for Wide Band Gap Semiconductor Materials and Devices of Education Ministry, School of Microelectronics, Xidian University, Xi'an 710071, China.
Hongxia LiuKey Laboratory for Wide Band Gap Semiconductor Materials and Devices of Education Ministry, School of Microelectronics, Xidian University, Xi'an 710071, China.ORCID 0000-0003-4547-0666
Shougang DuKey Laboratory for Wide Band Gap Semiconductor Materials and Devices of Education Ministry, School of Microelectronics, Xidian University, Xi'an 710071, China.
Shulong WangKey Laboratory for Wide Band Gap Semiconductor Materials and Devices of Education Ministry, School of Microelectronics, Xidian University, Xi'an 710071, China.ORCID 0000-0002-8560-2478
Hao ZhangKey Laboratory for Wide Band Gap Semiconductor Materials and Devices of Education Ministry, School of Microelectronics, Xidian University, Xi'an 710071, China.ORCID 0000-0001-9618-8746

Funding

National Natural Science Foundation of China U2241221
6 · The paper itself

Abstract

In order to detect biomolecules, a biosensor based on a dielectric-modulated stacked source trench gate tunnel field effect transistor (DM-SSTGTFET) is proposed. The stacked source structure can simultaneously make the on-state current higher and the off-state current lower. The trench gate structure will increase the tunneling area and tunneling probability. Technology computer-aided design (TCAD) is used for the sensitivity study of the proposed structured biosensor. The results show that the current sensitivity of the DM-SSTGTFET biosensor can be as high as 10

Indexed as

biosensordielectric modulated stacked source trench gate tunnel FET (DM-SSTGTFET)sensitivity

Identifiers

PMID36770492
PMCPMC9920143

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.