Evidence map›Paper›PMID 36770298›Full record

ArticleMaterials (Basel, Switzerland)2023

Tissue-Level Laser-Lok Implants Placed with a Flapless Technique: A 4-Year Clinical Study.

Andrea Spinelli, Fausto Zamparini, Georgios Romanos, Maria Giovanna Gandolfi, Carlo Prati

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Andrea SpinelliEndodontic Clinical Section, Department of Biomedical and Neuromotor Sciences, School of Dentistry, University of Bologna, 40125 Bologna, Italy.
Fausto ZampariniEndodontic Clinical Section, Department of Biomedical and Neuromotor Sciences, School of Dentistry, University of Bologna, 40125 Bologna, Italy.ORCID 0000-0002-0071-4463
Georgios RomanosDepartment of Periodontics and Endodontics, School of Dental Medicine, Stony Brook, NY 11794, USA.ORCID 0000-0002-7745-5957
Maria Giovanna GandolfiLaboratory of Biomaterials and Oral Pathology, Department of Biomedical and Neuromotor Sciences, School of Dentistry, University of Bologna, 40125 Bologna, Italy.ORCID 0000-0001-7793-6227
Carlo PratiEndodontic Clinical Section, Department of Biomedical and Neuromotor Sciences, School of Dentistry, University of Bologna, 40125 Bologna, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe present study aims to analyze the use of Laser-Lok microtextured neck implants placed with a transmucosal surgical approach. The marginal bone level (MBL) and periodontal parameters were evaluated in a cohort prospective 4-year clinical study.

methodsA total of 41 implants were placed in 36 healthy consecutive patients (16 males, 20 females, mean age 60 ± 9 years). Tapered tissue level implants, characterized by a 2.0 mm laser-microtextured neck, were used with a flapless approach. Customized abutments and provisional resin crowns were positioned. Definitive metal-ceramic crowns were cemented approximately 4 months after insertion. Periapical radiographs were taken after 1, 3, 6, 12, 36 and 48 months from implant placement to evaluate MBL. Gingival thickness (thin/thick), plaque score (PS) and bleeding on probing (BoP) were evaluated.

resultsAfter 48 months, all implants were safe from complications. No complications, peri-implantitis, early implant failures or mucositis occurred. The survival rate was 100%. Mean MBL during the follow-up was -0.15 ± 0.18 at T1, -0.29 ± 0.29 at T3, -0.45 ± 0.37 at T6, -0.53 ± 0.45 at T12, -1.06 ± 1.13 at T 36 and -1.10 ± 0.89 at T 48. Implants placed 2-3 months after tooth extraction revealed lower MBL variation when compared to those placed immediately (in fresh extraction sockets) or in completely healed ridges (delayed group). Narrower diameter implants (3.8 mm) showed significantly higher MBL variation when compared to 4.6 diameter implants. Multilevel analysis at T48 revealed that among all the evaluated variables, implant diameter was the factor mostly associated with MBL modifications (

conclusionThis 4-year clinical study supports the use of Laser-Lok implants placed at tissue level with a flapless approach. A limited bone loss during the 48-month follow-up was observed. Periodontal parameters were stable with no sign of inflammation or soft tissue alteration. The use of Laser-Lok implants with transmucosal surgery represents a suitable technique with a minimally invasive approach.

Indexed as

dental implantsflapless surgerylaser-lokmarginal bone leveltapered tissue level implant

Identifiers

PMID36770298
PMCPMC9919502

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.