Evidence map›Paper›PMID 36769756›Full record

ArticleJournal of clinical medicine2023

Spectral Dual-Layer Computed Tomography Can Predict the Invasiveness of Ground-Glass Nodules: A Diagnostic Model Combined with Thymidine Kinase-1.

Tong Wang, Yong Yue, Zheng Fan, Zheng Jia, Xiuze Yu, Chen Liu, Yang Hou

Abstract read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Predictive value of spectral dual-detector computed tomography forQuantitative imaging in medicine and surgery · 2024
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Tong WangDepartment of Radiology, Shengjing Hospital of China Medical University, Shenyang 110004, China.ORCID 0000-0002-5705-8364
Yong YueDepartment of Radiology, Shengjing Hospital of China Medical University, Shenyang 110004, China.
Zheng FanDepartment of Orthopedics, Shengjing Hospital of China Medical University, Shenyang 110004, China.
Zheng JiaPhilips (China) Investment Co., Ltd., Shanghai 200072, China.
Xiuze YuDepartment of Radiology, Shengjing Hospital of China Medical University, Shenyang 110004, China.
Chen LiuDepartment of Radiology, Shengjing Hospital of China Medical University, Shenyang 110004, China.
Yang HouDepartment of Radiology, Shengjing Hospital of China Medical University, Shenyang 110004, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesFew studies have explored the use of spectral dual-layer detector-based computed tomography (SDCT) parameters, thymidine kinase-1 (TK1), and tumor abnormal protein (TAP) for the detection of ground-glass nodules (GGNs). Therefore, we aimed to evaluate the quantitative and qualitative parameters generated from SDCT for predicting the pathological subtypes of GGN-featured lung adenocarcinoma combined with TK1 and TAP. MATERIAL AND

methodsBetween July 2021 and September 2022, 238 patients with GGNs were retrospectively enrolled in this study. SDCT and tests for TK1 and TAP were performed preoperatively, and the lesions were divided into glandular precursor lesions (PGL), minimally invasive adenocarcinoma (MIA), and invasive adenocarcinoma (IAC), according to the pathological results. A receiver operating characteristic (ROC) curve was used to compare the diagnostic performance of these parameters. Multivariate logistic regression analysis was performed to construct a joint diagnostic model and create a nomogram.

resultsThis study included 238 GGNs, including 41 atypical adenomatous hyperplasias (AAH), 62 adenocarcinomas in situ (AIS), 49 MIA, and 86 IAC, with a high proportion of women, non-smokers, and pure ground-glass nodule (pGGN). CT100 keV (a/v), electronic density (EDW) (a/v), Daverage, Dsolid, TK1, and TAP of MIA and IAC were higher than those of PGL. The effective atomic number (Zeff (a/v)) was lower in MIA and IAC than in PGL (all

conclusionsMultiple quantitative and functional parameters can be selected based on SDCT, especially Zeff (a) and EDW (a), which have high sensitivity and specificity for predicting GGNs' invasiveness. Additionally, the combination of TK1 can further improve diagnostic performance, and using a nomogram is helpful for individualized predictions.

Indexed as

ground-glass nodulelung adenocarcinomaquantitative and qualitative parametersspectral computed tomographythymidine kinase-1

Identifiers

PMID36769756
PMCPMC9917490

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390