Evidence map›Paper›PMID 36765167›Full record

ArticleScientific reports2023

Reliability of coracohumeral distance and subcoracoid tendons in subacromial pain syndrome.

Claudia Cavaggion, Santiago Navarro-Ledesma, Birgit Juul-Kristensen, Alejandro Luque-Suarez, Lennard Voogt, Filip Struyf

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 4 countries.

Claudia CavaggionResearch Group MOVANT, Department of Rehabilitation Sciences and Physiotherapy, Faculty of Medicine and Health Sciences, University of Antwerp, Campus Drie Eiken, Universiteitsplein 1, 2610, Wilrijk, Belgium.
Santiago Navarro-LedesmaDepartment of Physiotherapy, University of Granada, Faculty of Health Sciences, Campus of Melilla, Querol Street, 5, 52004, Melilla, Spain. snl@ugr.es.
Birgit Juul-KristensenDepartment of Sports Science and Clinical Biomechanics, University of Southern Denmark, Campusvej 55, 5230, Odense M, Denmark.
Alejandro Luque-SuarezDepartment of Physiotherapy, Universidad de Malaga, Arquitecto Penalosa S/N, 29002, Malaga, Spain.
Lennard VoogtDepartment of Physical Therapy Studies and Research Centre for Health Care Innovations, Rotterdam University of Applied Sciences, Rochussenstraat 198, 3015EK, Rotterdam, The Netherlands.
Filip StruyfResearch Group MOVANT, Department of Rehabilitation Sciences and Physiotherapy, Faculty of Medicine and Health Sciences, University of Antwerp, Campus Drie Eiken, Universiteitsplein 1, 2610, Wilrijk, Belgium.
University of Antwerp · BEUniversidad de Granada · ESUniversidad de Málaga · ESUniversity of Southern Denmark · DKVrije Universiteit Brussel · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study investigated the intra-rater reliability of a novice ultrasound (US) examiner and the inter-rater reliability of two examiners (novice, expert) in the measures of coracohumeral distance at rest (CHD) and at 60° of elevation without (CHD60) or with weights (CHD60w), tendon thickness of the long head of the biceps (LHB) and subscapularis (SCP). Twenty-one patients with subacromial pain syndrome (SAPS) and 20 asymptomatic participants were included. Intra and inter-rater reliability were tested with intraclass-correlation-coefficient (ICC), differences between raters were analyzed with Bland-Altman plots. Intra-rater reliability for CHD, CHD60 and CHD60w was excellent (ICC = 0.97-0.98) in asymptomatic participants, and good-to-excellent (0.88-0.93) in SAPS, while intra-rater reliability for LHB and SCP was good-to-excellent in asymptomatic participants (0.88-0.97) and in SAPS (0.90-0.92). Inter-rater reliability for CHD, CHD60 and CHD60w was moderate-to-good (0.70-0.90) in asymptomatic participants and good (0.85-0.87) in SAPS, in contrast inter-rater reliability for LHB and SCP was poor in asymptomatic participants (0.10-0.46) and poor-to-moderate (0.49-0.61) in SAPS. Bland-Altman plots revealed systematic and/or proportional bias for tendons' thickness. A novice showed good-to-excellent intra-rater reliability in all US measures, whereas in comparison to an expert a novice can measure reliably CHD, CHD60 and CHD60w, but not LHB and SCP, where more training is recommended.

Indexed as

Rotator CuffTendonsHumansObserver VariationPainReproducibility of Results

Identifiers

PMID36765167
PMCPMC9918475
OpenAlexW4319970119

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.