Evidence map›Paper›PMID 36763197›Full record

ArticleBiomechanics and modeling in mechanobiology2023

Fluid-structure interaction modeling of compliant aortic valves using the lattice Boltzmann CFD and FEM methods.

Adi Morany, Karin Lavon, Ricardo Gomez Bardon, Brandon Kovarovic, Ashraf Hamdan, Danny Bluestein, Rami Haj-Ali

Abstract read
In one paragraph

Article in Biomechanics and modeling in mechanobiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Adi MoranySchool of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel.
Karin LavonSchool of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel.
Ricardo Gomez BardonDassault Systemes España, Madrid, Spain.
Brandon KovarovicDepartment of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA.
Ashraf HamdanDepartment of Cardiology, Rabin Medical Center, Petach Tikva, Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
Danny BluesteinDepartment of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA.
Rami Haj-AliSchool of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel. rami98@tau.ac.il.

Funding

Biomechanical Approaches and Technologies for Enhancing TAVR OutcomesU01EB026414 · NIBIB · STATE UNIVERSITY NEW YORK STONY BROOK · PI BLUESTEIN, DANNY · 2018 to 2022
$3.8M
NIBIB NIH HHS U01 EB026414NIH HHS U01- EB026414
6 · The paper itself

Abstract

The lattice Boltzmann method (LBM) has been increasingly used as a stand-alone CFD solver in various biomechanical applications. This study proposes a new fluid-structure interaction (FSI) co-modeling framework for the hemodynamic-structural analysis of compliant aortic valves. Toward that goal, two commercial software packages are integrated using the lattice Boltzmann (LBM) and finite element (FE) methods. The suitability of the LBM-FE hemodynamic FSI is examined in modeling healthy tricuspid and bicuspid aortic valves (TAV and BAV), respectively. In addition, a multi-scale structural approach that has been employed explicitly recognizes the heterogeneous leaflet tissues and differentiates between the collagen fiber network (CFN) embedded within the elastin matrix of the leaflets. The CFN multi-scale tissue model is inspired by monitoring the distribution of the collagen in 15 porcine leaflets. Different simulations have been examined, and structural stresses and resulting hemodynamics are analyzed. We found that LBM-FE FSI approach can produce good predictions for the flow and structural behaviors of TAV and BAV and correlates well with those reported in the literature. The multi-scale heterogeneous CFN tissue structural model enhances our understanding of the mechanical roles of the CFN and the elastin matrix behaviors. The importance of LBM-FE FSI also emerges in its ability to resolve local hemodynamic and structural behaviors. In particular, the diastolic fluctuating velocity phenomenon near the leaflets is explicitly predicted, providing vital information on the flow transient nature. The full closure of the contacting leaflets in BAV is also demonstrated. Accordingly, good structural kinematics and deformations are captured for the entire cardiac cycle.

Indexed as

Aortic ValveBicuspid Aortic Valve DiseaseAnimalsCollagenElastinHemodynamicsModels, CardiovascularSwineCollagenElastinAortic valve biomechanicsFinite element (FE)Fluid–structure interaction (FSI)Lattice Boltzmann method (LBM)

Identifiers

PMID36763197
PMCPMC12077742

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.