Evidence map›Paper›PMID 36748441›Full record

ArticleEuropean endodontic journal2023

Advanced Electrochemical Reamer (EC-Reamer) for Root Canal Treatment.

Remya Ampadi Ramachandran, Wei Li, Shweta Khande, Ahish Shylendra, Amit Ranjan Trivedi, Qian Xie, Christine Wu, Mathew Thoppil Mathew

Open access · diamondAbstract read
In one paragraph

Article in European endodontic journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 51% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Remya Ampadi RamachandranDepartment of Biomedical Engineering, University of Illinois at Chicago, Chicago, USA.
Wei LiDepartment of Pediatric Dentistry, College of Dentistry, University of Illinois at Chicago, Chicago, USA.
Shweta KhandeDepartment of Biomedical Engineering, University of Illinois at Chicago, Chicago, USA.
Ahish ShylendraDepartment of Electrical and Computer Engineering, University of Illinois at Chicago, Chicago, USA.
Amit Ranjan TrivediDepartment of Electrical and Computer Engineering, University of Illinois at Chicago, Chicago, USA.
Qian XieDepartment of Endodontics, College of Dentistry, University of Illinois at Chicago, Chicago, USA.
Christine WuDepartment of Pediatric Dentistry, College of Dentistry, University of Illinois at Chicago, Chicago, USA.
Mathew Thoppil MathewDepartment of Biomedical Engineering, University of Illinois at Chicago, Chicago, USA; Department of Restorative Dentistry, College of Dentistry, University of Illinois at Chicago, Chicago, USA.
University of Illinois Chicago · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveAccording to the American Association of Endodontists (AAE), 22 million endodontic procedures have been performed annually. Root canal treatment is needed to prevent infection and restore function when a tooth is severely infected or decayed. This procedure is the only way to preserve the natural tooth and avoid artificial replacement (implant, denture, etc.). The current study aims to develop an electrochemical reamer (EC-Reamer or EC-R) that can help to disinfect the canal system and thus improve the success rate of root canal treatment.

methodsThe COMSOL Multiphysics software was utilized to simulate the experimental setup and confirm the current flow in the electrolyte. The benchtop experimental approach follows a specific electrochemical protocol, (i) open circuit potential to monitor the electrochemical stabilization and (ii) potentiostatic scan at -9.0 V as the treatment stage. Identification of feasible reference electrode (RE) and insulation material for the exploratory benchtop studies considered platinum (Pt) and gold (Au) wire as the REs and hot melt adhesive (HMA) and liquid tape as the insulation materials. The antimicrobial effects of EC-R were analysed using Enterococcus faecalis (E. faecalis). One-way ANOVA with the Tukey post hoc test and a significance level of P<0.05 is used to compare the groups with an experimental duration of 60 seconds.

resultsThe findings showed that magnitude and current fluctuations created by Pt wire are promising when compared to Au wire, while Pt-HMA pair is chosen considering Pt's good electrochemical inertness and HMA's easy handling, availability, and non-hazardous features. The use of potentiostatic duration of 1 s and 3 s resulted in >99.99% E. faecalis reduction. Duration at 5 s and above resulted in a total bacterial kill. Statistical analysis confirmed a significant difference among the groups tested with commercial and custom-built potentiostats.

conclusionThe outcome provided preliminary data for developing an EC-R prototype to enhance the antimicrobial effect during root canal treatment potentially. (EEJ-2022-01-04).

Indexed as

Anti-Infective AgentsDental Pulp CavityRoot Canal TherapyAnti-Infective Agents

Identifiers

PMID36748441
PMCPMC10098461
OpenAlexW4292572373

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.