ArticleMagnetic resonance in medicine2023
Motion guidance lines for robust data consistency-based retrospective motion correction in 2D and 3D MRI.
Article in Magnetic resonance in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 12 citations in OpenAlex.
- Prospective Head Motion Correction in T1- and T2-Weighted Long Echo Train Sequences Using Servo Navigation.Magnetic resonance in medicine · 2026Article
- A network-assisted joint image and motion estimation approach for robust 3D MRI motion correction across severity levels.Magnetic resonance in medicine · 2026Article
- A foundation model for enhancing magnetic resonance images and downstream segmentation, registration and diagnostic tasks.Nature biomedical engineering · 2025Article
- Prospective 3D Fat Navigator (FatNav) motion correction for 7T Terra MRI.NMR in biomedicine · 2025Article
- Sequence-agnostic motion-correction leveraging efficiently calibrated Pilot Tone signals.Magnetic resonance in medicine · 2024Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 4 institutions in 3 countries.
Funding
Abstract
purposeTo develop a robust retrospective motion-correction technique based on repeating k-space guidance lines for improving motion correction in Cartesian 2D and 3D brain MRI.
methodsThe motion guidance lines are inserted into the standard sequence orderings for 2D turbo spin echo and 3D MPRAGE to inform a data consistency-based motion estimation and reconstruction, which can be guided by a low-resolution scout. The extremely limited number of required guidance lines are repeated during each echo train and discarded in the final image reconstruction. Thus, integration within a standard k-space acquisition ordering ensures the expected image quality/contrast and motion sensitivity of that sequence.
resultsThrough simulation and in vivo 2D multislice and 3D motion experiments, we demonstrate that respectively 2 or 4 optimized motion guidance lines per shot enables accurate motion estimation and correction. Clinically acceptable reconstruction times are achieved through fully separable on-the-fly motion optimizations (˜1 s/shot) using standard scanner GPU hardware.
conclusionThe addition of guidance lines to scout accelerated motion estimation facilitates robust retrospective motion correction that can be effectively introduced without perturbing standard clinical protocols and workflows.