Evidence map›Paper›PMID 36743726›Full record

ArticleOrthopaedic journal of sports medicine2023

Compressibility of Osteochondral Autograft Transfer Donor Grafts: A Comparison of Different Donor Regions and How Much Shortening Occurs of Plugs After Impaction.

Patrick A Massey, Rachel Kushner, Cole Miller, Michael Lowery, Richard S Barton, Giovanni F Solitro

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.5field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Patrick A MasseyDepartment of Orthopaedic Surgery, Louisiana State University, Shreveport, Louisiana, USA.
Rachel KushnerDepartment of Orthopaedic Surgery, Louisiana State University, Shreveport, Louisiana, USA.
Cole MillerSchool of Medicine, Louisiana State University, Shreveport, Louisiana, USA.
Michael LoweryDepartment of Orthopaedic Surgery, Louisiana State University, Shreveport, Louisiana, USA.
Richard S BartonDepartment of Orthopaedic Surgery, Louisiana State University, Shreveport, Louisiana, USA.
Giovanni F SolitroDepartment of Orthopaedic Surgery, Louisiana State University, Shreveport, Louisiana, USA.
Louisiana State University in Shreveport · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Osteochondral autograft transfer (OAT) is a useful technique for full-thickness cartilage lesions of the distal femur. Various techniques recommend harvesting a plug 2 mm longer than the recipient hole to allow for graft impaction. Grafts with limited compressibility may not sit flush when impacted. Purpose: To compare the compressibility/shortening of OAT donor plug regions from the distal femur of human cadaveric knees after impaction. Study Design: Controlled laboratory study. Methods: A total of 20 cadaveric knees (mean age, 70.3 ± 8.4 years) were divided into 4 donor regions: medial intercondylar (IC) notch, lateral IC notch, medial trochlea, and lateral trochlea. Each region was subdivided into 4 zones: far superior (FSZ), middle superior (MSZ), middle inferior (MIZ), and far inferior (FIZ). A total of 320 grafts (6-mm diameter, 15-mm depth) were extracted, and a custom-built machine was used to strike the graft 5 times using a predetermined energy of 0.11 J. The graft length was measured initially and after each impact. Statistical analysis of the compressibility for each of the 4 regions and all 16 zones was performed utilizing analysis of variance, with post hoc testing using the Fisher's least significant difference. Results: Compression in the lateral IC notch, medial IC notch, medial trochlea, and lateral trochlea was 2.4 ± 1.5, 2.1 ± 0.7, 3.1 ± 2.2, and 2.1 ± 0.6 mm, respectively, with significant differences between the 4 regions ( Conclusion: Compressibility varied between OAT donor sites in the distal femur. OAT donor grafts showed the highest compressibility in the medial trochlea (3.1 mm) and lateral IC notch FSZ (3.0 mm). Clinical Relevance: The lateral trochlea, medial IC notch, and the lower zones of the lateral IC notch grafts should not be oversized more than 2 mm in length, as these grafts may not compress adequately.

Indexed as

articular cartilagebiomechanics articular cartilagecompressibilitykneeosteochondral autograft transplant (OAT)

Identifiers

PMID36743726
PMCPMC9893359
OpenAlexW4319293690

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390