Evidence map›Paper›PMID 36742072›Full record

ArticleFrontiers in cardiovascular medicine2023

Case report: Successful percutaneous extracorporeal magnetic levitation ventricular assist device support in a patient with left heart failure due to dilated cardiomyopathy.

Ping Li, Xiaoying Zhang, Shu Chen, Po-Lin Hsu, Tingting Wu, Shirui Qian, Wei Su, Guohua Wang, Nianguo Dong

Abstract readCase Reports
In one paragraph

Article in Frontiers in cardiovascular medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Progress of extracorporeal centrifugal pumps for mechanical circulatory supports.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2025
    Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ping LiDepartment of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
Xiaoying ZhangmagAssist, Inc., Suzhou, Jiangsu, China.
Shu ChenDepartment of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
Po-Lin HsumagAssist, Inc., Suzhou, Jiangsu, China.
Tingting WumagAssist, Inc., Suzhou, Jiangsu, China.
Shirui QianDepartment of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
Wei SuDepartment of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
Guohua WangDepartment of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
Nianguo DongDepartment of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Mechanical circulatory support (MCS) can help to maintain hemodynamic stability, improve cardiac function, reduce cardiac load, and is an important method for the treatment of advanced heart failure. However, traditional MCS systems [IABP, Impella, TandemHerat, veno-arterial extracorporeal membrane oxygenation (VA-ECMO)] are associated with limitations including trauma, a high rate of complications (hemolysis, bleeding) and require complex care from nurses. Case summary: We report a case of left heart failure resulting from dilated cardiomyopathy in a 24 years-old man. A catheter was placed through the right jugular vein and a drainage tube was positioned under ultrasound guidance through the superior vena cava, right atrium, atrial septum, to the left atrium, and returned to the axillary artery using an extracorporeal magnetic levitation ventricular assist device (VAD). The patient was successfully supported for 10 days and bridged to heart transplant. Discussion: To the best of our knowledge, this is the first report of the use of an extracorporeal magnetic levitation VAD for MCS

Indexed as

extracorporeal ventricular assist deviceheart failuremaglevminimally invasivepercutaneous mechanical circulatory support

Identifiers

PMID36742072
PMCPMC9892048

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.