Evidence map›Paper›PMID 36733657›Full record

ArticleThe Canadian veterinary journal = La revue veterinaire canadienne2023

A prospective survey of veterinary anesthesia equipment in Alberta, Canada, using a standardized checkout procedure.

Jocelyn J M Marchiori, Melanie J Prebble, Daniel S J Pang

Open access · greenAbstract read
In one paragraph

Article in The Canadian veterinary journal = La revue veterinaire canadienne, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Jocelyn J M MarchioriWestern Veterinary Specialist and Emergency Centre, 1802 10th Avenue SW, Calgary, Alberta T3C 0J8 (Marchiori); Dispomed Ltd, 745 Rue Nazaire Laurin, Joliette, Québec J6E 0L6 (Prebble); Department of Veterinary Clinical and Diagnostic Sciences, Faculty of Veterinary Medicine, University of Calgary, 3280 Hospital Drive NW, Calgary, Alberta T2N 4Z6 (Pang); Department of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, 3200, rue Sicotte Saint-Hyacinthe, Québec J2S 2M2 (Pang).
Melanie J PrebbleWestern Veterinary Specialist and Emergency Centre, 1802 10th Avenue SW, Calgary, Alberta T3C 0J8 (Marchiori); Dispomed Ltd, 745 Rue Nazaire Laurin, Joliette, Québec J6E 0L6 (Prebble); Department of Veterinary Clinical and Diagnostic Sciences, Faculty of Veterinary Medicine, University of Calgary, 3280 Hospital Drive NW, Calgary, Alberta T2N 4Z6 (Pang); Department of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, 3200, rue Sicotte Saint-Hyacinthe, Québec J2S 2M2 (Pang).
Daniel S J PangWestern Veterinary Specialist and Emergency Centre, 1802 10th Avenue SW, Calgary, Alberta T3C 0J8 (Marchiori); Dispomed Ltd, 745 Rue Nazaire Laurin, Joliette, Québec J6E 0L6 (Prebble); Department of Veterinary Clinical and Diagnostic Sciences, Faculty of Veterinary Medicine, University of Calgary, 3280 Hospital Drive NW, Calgary, Alberta T2N 4Z6 (Pang); Department of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, 3200, rue Sicotte Saint-Hyacinthe, Québec J2S 2M2 (Pang).
University of Calgary · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: In both human and veterinary medicine, it is recommended that an anesthetic machine checkout procedure (preuse check) be performed daily, with some items tested before each case, to confirm safe function and the check results recorded. Objective: The objective of this prospective study was to evaluate anesthetic machines in private veterinary clinics in Alberta (Canada) using a standardized checkout procedure. Animals and procedures: One-hundred consecutive anesthetic machines were assessed. For each item of the checkout procedure, a "pass," "fail," or "not applicable" score was awarded. "Not applicable" indicated an item that could not be evaluated. Results: Few machines (10%) evaluated had a secondary oxygen supply, no machines had an oxygen supply pressure alarm, and leaks were identified in 31 and 17% of rebreathing and non-rebreathing systems, respectively. Thirty-nine percent of machines did not have a high-pressure circuit alarm, 86% of machines were attached to an active scavenging system, although it was improperly connected in 56% of cases, and only 2% of machines were accompanied by a checkout log. Conclusion and clinical relevance: There was widespread variation in anesthetic machine standards and function, highlighting the value of performing a regular machine checkout procedure in creating a foundation for safe anesthetic practice.

Indexed as

AnesthesiaAlbertaAnimalsHumansOxygenProspective StudiesSurveys and QuestionnairesOxygen

Identifiers

PMID36733657
PMCPMC9847401
OpenAlexW4319058255

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.