Evidence map›Paper›PMID 36732725›Full record

ArticleBMC musculoskeletal disorders2023

Bionic reconstruction of tension trabeculae in short-stem hip arthroplasty: a finite element analysis.

Zhentao Ding, Jun Wang, Yanhua Wang, Xiaomeng Zhang, Yong Huan, Dianying Zhang

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
1.9field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 6 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Zhentao Ding *Department of Orthopedics and Trauma, Peking University People's Hospital, Beijing, 100044, China.
Jun Wang *State Key Laboratory of Nonlinear Mechanics (LNM), Institute of Mechanics, Chinese Academy of Sciences, Beijing, 100190, China.
Yanhua Wang *Department of Orthopedics and Trauma, Peking University People's Hospital, Beijing, 100044, China.
Xiaomeng ZhangDepartment of Orthopedics and Trauma, Peking University People's Hospital, Beijing, 100044, China.
Yong HuanState Key Laboratory of Nonlinear Mechanics (LNM), Institute of Mechanics, Chinese Academy of Sciences, Beijing, 100190, China. huany@lnm.imech.ac.cn.
Dianying ZhangDepartment of Orthopedics and Trauma, Peking University People's Hospital, Beijing, 100044, China. zdy8016@163.com.
Peking University People's Hospital · CNChinese Academy of Sciences · CNMinistry of Education · ROUniversity of Chinese Academy of Sciences · CN

Funding

Peking University People's Hospital Scientific Research Development Funds PTU2021-06
6 · The paper itself

Abstract

backgroundShort-stem hip arthroplasty (SHA) is characterized by metaphyseal load transfer that effectively preserves the bone stock, but still suffers from stress shielding in the proximal femur. We designed a tension screw to mimic tension trabeculae in the new bionic collum femoris preserving (BCFP) short stem for bionic reconstruction, aiming to restore the biomechanics of hip joint.

methodsNative femur finite element model was constructed to investigate the biomechanics of hip joint based on computed tomography (CT) data. The maximum absolute principal stress/strain cloud chart allowed the direction of stress/strain to be assessed. Six BCFP models with different screw angles (5°, 10°, 15°, 20°, 25°, and 30°) and the Corail model were created. The stress/strain distribution and overall stiffness were compared between each of the BCFP and Corail implanted models.

resultsThe native model visualized the transfer pathways of tensile and compressive stress. The BCFP stems showed significantly higher stress and strain distribution in the greater trochanteric region compared to conventional total hip arthroplasty (THA). In particular, the BCFP-5° stem demonstrated the highest average strain in both medial and lateral regions and the overall stiffness was closest to the intact femur.

conclusionsStress transfer pathways of trabecular architecture provide biomechanical insight that serves as the basis for bionic reconstruction. The tension screw improves load transfer pattern in the proximal femur and prevents stress reduction in the greater trochanteric region. The BCFP-5° stem minimizes the stress shielding effect and presents a more bionic mechanical performance.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisBiomechanical PhenomenaBionicsFemurFinite Element AnalysisHumansProsthesis DesignStress, MechanicalBionic reconstructionFinite element analysisHip biomechanicsShort-stem hip arthroplastyStress shieldingTension screw

Identifiers

PMID36732725
PMCPMC9893650
OpenAlexW4319029711

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked