ArticleThe ultrasound journal2023
Ultrasonographic measurement of the optic nerve sheath diameter to detect intracranial hypertension: an observational study.
Article in The ultrasound journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 1 synthesis or guideline pooled it, 31 citations in OpenAlex.
- Sonographic optic nerve sheath diameter measurement for detecting intracranial hypertension in a suspected population: a systematic review and meta-analysis of diagnostic thresholds and influencing factors.Journal of neurology · 2026Pooled it
- Lumbar Puncture and Brain Herniation in Acute Bacterial Meningitis: An Updated Narrative Review.Journal of intensive care medicine · 2026Review
- Effect of Tonsillar Retractor on Intracranial and Intraocular Pressure in Children Undergoing Adenotonsillectomy Surgeries.Laryngoscope investigative otolaryngology · 2026Article
- Characterizing Initial Cervical Spine and Neurovascular Findings in 84 Consecutive Patients with Hypermobile Ehlers-Danlos Syndrome: A Retrospective Study.Journal of clinical medicine · 2026Article
- Predictive value of optic nerve sheath diameters on cerebral performance category scale in patients with impaired consciousness in the emergency department: a prospective pilot study.International journal of emergency medicine · 2026Article
- Artificial Intelligence in the Diagnostic Use of Transcranial Doppler and Sonography: A Scoping Review of Current Applications and Future Directions.Bioengineering (Basel, Switzerland) · 2025Review
- Effects of dexmedetomidine and sevoflurane on optic nerve sheath diameter and postoperative nausea and vomiting in patients undergoing microvascular decompression: a retrospective cohort study.BMC anesthesiology · 2025Article
- Article
- Effect on the size of optic nerve sheath diameter in patients undergoing surgeries under spinal anaesthesia versus peripheral nerve blocks - A randomised controlled study.Indian journal of anaesthesia · 2025Article
- From Cadavers to Soundwaves: The Evolution of Autopsy in Medical Diagnosis and the Rise of Point-of-Care Ultrasound.Cureus · 2025Review
- Optic nerve sonographic parameters in idiopathic intracranial hypertension, case-control study.Scientific reports · 2025Article
- The Brussels consensus for non-invasive ICP monitoring when invasive systems are not available in the care of TBI patients (the B-ICONIC consensus, recommendations, and management algorithm).Intensive care medicine · 2025Article
- Optic Nerve Sheath Measurement on Ultrasound: A Novel Diagnostic Test for Giant Cell Arteritis.ACR open rheumatology · 2024Article
- Article
- Brain-based symptoms reported in young adults evaluated for cervical spine etiology: a retrospective, cross-sectional clinical study with preliminary data on over 200 patients.Frontiers in neurologyArticle
- Assessment of optic nerve sheath enlargement and Frisen classification in idiopathic intracranial hypertension: Implications for estimating intracranial pressure and grading chronic papilledema.Taiwan journal of ophthalmologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo evaluate the ultrasonographic measurement of optic nerve sheath diameter (ONSD) as a predictor of intracranial hypertension as compared to the invasive measurement of intracranial pressure (ICP).
designCross-sectional observational study.
settingIntensive Care Unit (ICU) of two tertiary university hospitals in Montevideo, Uruguay. PATIENTS: We included 56 adult patients, over 18 years of age, who required sedation, mechanical ventilation, and invasive ICP monitoring as a result of a severe acute neurologic injury (traumatic or non-traumatic) and had a Glascow Coma Score (GCS) equal to or less than 8 on admission to the ICU.
interventionsUltrasonographic measurement of ONSD to detect intracranial hypertension. MEASUREMENTS AND MAIN
resultsIn our study, a logistic regression model was performed in which it was observed that the variable ONSD is statistically significant with a p value of 0.00803 (< 0.05). This model estimates and predicts the probability that a patient will have an ICP greater than 20 mmHg. From the analysis of the cut-off points, it is observed that a value of 5.7 mm of ONSD maximizes the sensitivity (92.9%) of the method (a greater number of individuals with ICP > 20 mmHg are correctly identified).
conclusionsIn sedated neurocritical patients, with structural Acute Brain Injury, the ONSD measurement correlates with the invasive measurement of ICP. It was observed that with ONSD values less than 5.7 mm, the probability of being in the presence of ICP above 20 mmHg is very low, while for ONSD values greater than 5.7 mm, said probability clearly increases.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials