Evidence map›Paper›PMID 36726420›Full record

ArticleJournal of medical signals and sensors

A Scoring Framework and Apparatus for Epilepsy Seizure Detection Using a Wearable Belt.

Salah Eldeen Moleh Falah Alzghoul, Sa'ed Ahmad Qwaiteen Alajlouni

Abstract read
In one paragraph

Article in Journal of medical signals and sensors. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Salah Eldeen Moleh Falah AlzghoulDepartment of Biomedical Engineering, Faculty of Engineering, The Hashemite University, Zarqa, Jordan.
Sa'ed Ahmad Qwaiteen AlajlouniDepartment of Mechatronics Engineering, Faculty of Engineering, The Hashemite University, Zarqa, Jordan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To develop a wearable device that can detect epilepsy seizures. In particular, due to their prevalence, attention is focused on detecting the generalized tonic-clonic seizure (GTCS) type. When a seizure is detected, an alert phone call is initiated and an alarm SMS sent to the nearest health-care provider (and/or a predesignated family member), including the patient's location as global positioning system (GPS) coordinates. A wearable belt is developed including an Arduino processor that constantly acquires data from four different sensing modalities and monitors the acquired signal patterns for abnormalities. The sensors are a heart rate sensor, electromyography sensor, blood oxygen level (oxygen saturation) sensor, and an accelerometer to detect sudden falls. Higher-than-normal threshold levels are established for each sensor's signal. If two or more signal measurements exceed the corresponding threshold value for a predetermined time interval, then the seizure alarm is triggered. Clinical trials were not pursued in this study as this is the initial phase of system development (phase 0). Instead, the instrumented belt seizure detection prototype was tested on nine healthy individuals mimicking, to some degree, seizure symptoms. A total of eighteen trials took place of which half had <2 sensor thresholds exceeded and no alarm, whereas the other half resulted in activating the alarm when two or more sensor thresholds were exceeded for at least the predetermined time interval corresponding to each of the higher-than-normal sensor readings. For each trial that triggered the alarm when a seizure was detected, the on-board GPS and global system for mobile communication (GSM) units successfully initiated an alert phone call to a predesignated number in addition to sending an SMS message, including GPS location coordinates. Continuous real-time monitoring of signals from the four different sensors allows the developed wearable belt to detect GTCS while reducing false alarms. The proposed device produces an important alarm that may save a patient's life.

Indexed as

Alarm systemelectromyographyepilepsy seizuresheart ratesmart health-care systemwearable

Identifiers

PMID36726420
PMCPMC9885511

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.