Evidence map›Paper›PMID 36726086›Full record

ArticleBMC musculoskeletal disorders2023

Biomechanical evaluation of different sizes of 3D printed cage in lumbar interbody fusion-a finite element analysis.

Jincheng Wu, Qing Feng, Dongmei Yang, Hanpeng Xu, Wangqiang Wen, Haoxiang Xu, Jun Miao

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
5.4field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Jincheng Wu *Department of Spine Surgery, Tianjin Hospital, Tianjin University, Jiefangnanlu 406, Hexi District, Tianjin, China.
Qing Feng *Department of Spine Surgery, Tianjin Hospital, Tianjin University, Jiefangnanlu 406, Hexi District, Tianjin, China.
Dongmei Yang *Southern Medical University, Guangzhou City, Guangdong, China.
Hanpeng XuDepartment of Spine Surgery, Tianjin Hospital, Tianjin University, Jiefangnanlu 406, Hexi District, Tianjin, China.
Wangqiang WenThe First Affiliated Hospital of Hainan Medical University, Haikou City, Hainan, China.
Haoxiang XuThe Second People's Hospital of Hefei, Hefei, Anhui, China.
Jun MiaoDepartment of Spine Surgery, Tianjin Hospital, Tianjin University, Jiefangnanlu 406, Hexi District, Tianjin, China. mj6688@163.com.
Tianjin Hospital · CNTianjin University · CNHainan Medical University · CNSouthern Medical University · CN

Funding

National Natural Science Foundation of China 81472140Natural Science Foundation of Tianjin City S20ZDD484
6 · The paper itself

Abstract

objectiveTo study the biomechanical characteristics of various tissue structures of different sizes of 3D printed Cage in lumbar interbody fusion.

methodsA finite element model of normal spine was reconstructed and verified. Pedicle screws and Cage of different sizes were implanted in the L4/5 segment to simulate lumbar interbody fusion. The range of motion of the fixed and cephalic adjacent segment, the stress of the screw-rod system, the stress at the interface between cage and L5 endplate, and intervertebral disc pressure of the adjacent segment were calculated and analyzed.

resultsThe range of motion and intervertebral disc pressure of the adjacent segment of each postoperative model were larger than those of the intact model, but there was not much difference between them. The stress of cage-endplate interface was also larger than that of the intact model. However, the difference is that the stress of the endplate and the screw-rod system has a tendency to decrease with the increase of the axial area of cage.

conclusionsCage with larger axial area in lumbar interbody fusion can reduce the stress of internal fixation system and endplate, but will not increase the range of motion and intervertebral disc pressure of adjacent segment. It has a certain effect in preventing the cage subsidence, internal fixation system failure and screw rod fracture.

Indexed as

Pedicle ScrewsSpinal FusionBiomechanical PhenomenaFinite Element AnalysisHumansLumbar VertebraePrinting, Three-DimensionalRange of Motion, Articular3D printed cageCage subsidenceFinite element analysisLumbar interbody fusionNon-unionSpine

Identifiers

PMID36726086
PMCPMC9890703
OpenAlexW4318816332

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.