ReviewMagma (New York, N.Y.)2023
Commissioning of the Iseult CEA 11.7 T whole-body MRI: current status, gradient-magnet interaction tests and first imaging experience.
Review in Magma (New York, N.Y.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
22 citing papers in PubMed.
- Design of an 8-Channel Transmit 32-Channel Receive 11.7T Head Coil and Evaluation of SNR Gains.Magnetic resonance in medicine · 2026Article
- Magnetic resonance imaging.Science advances · 2026Review
- Low-AC-Loss Nb3Sn Validation Model Coil in Solid Nitrogen for a Fast-Switching-Field MRI Magnet Prototype.IEEE transactions on applied superconductivity : a publication of the IEEE Superconductivity Committee · 2026Article
- Motion- and Field-Robust Mesoscopic Whole-BrainMagnetic resonance in medicine · 2026Article
- BOLD fMRI at 9.4T with 3D stack-of-spirals readouts.Magma (New York, N.Y.) · 2026Article
- Human fMRI at 11.7T: Assessing feasibility, stability, and reliability on the Iseult scanner.Imaging neuroscience (Cambridge, Mass.) · 2026Article
- Radiological Correlates of Head Injuries in School-Level Rugby Union: A 10-Year Retrospective Cross-Sectional Analysis.Sports medicine (Auckland, N.Z.) · 2025Article
- 500 MHz Inductive Birdcage RF Coil for Brain MRI: Design, Implementation and Validation.IEEE transactions on bio-medical engineering · 2025Article
- A 128-channel receive array with enhanced signal-to-noise ratio performance for 10.5T brain imaging.Magnetic resonance in medicine · 2025Article
- Exploring in vivo human brain metabolism at 10.5 T: Initial insights from MR spectroscopic imaging.NeuroImage · 2025Article
- Quo Vadis MRI?Zeitschrift fur medizinische Physik · 2025Article
- 3D Metamaterials Facilitate Human Cardiac MRI at 21.0 Tesla: A Proof-of-Concept Study.Sensors (Basel, Switzerland) · 2025Article
- Effects of 16.8-22.0 T high static magnetic fields on the development of zebrafish in early fertilization.European radiology · 2024Article
- In vivo imaging of the human brain with the Iseult 11.7-T MRI scanner.Nature methods · 2024Article
- Acoustic noise reduction in the NexGen 7 T scanner.Magnetic resonance in medicine · 2024Article
- Harmonic errors of a 9.4 T all-REBCO NMR magnet affected by screening current and geometric inconsistency of coated conductors.Scientific reports · 2024Article
- AC Loss Measurement in NbIEEE transactions on applied superconductivity : a publication of the IEEE Superconductivity Committee · 2024Article
- Neuroimaging and fluid biomarkers in Parkinson's disease in an era of targeted interventions.Nature communications · 2024Review
- Ultra-High Contrast MRI: The Whiteout Sign Shown with Divided Subtracted Inversion Recovery (dSIR) Sequences in Post-Insult Leukoencephalopathy Syndromes (PILS).Tomography (Ann Arbor, Mich.) · 2024Review
- The possible influence of third-order shim coils on gradient-magnet interactions: an inter-field and inter-site study.Magma (New York, N.Y.) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
objectivesThe Iseult MRI is an actively shielded whole-body magnet providing a homogeneous and stable magnetic field of 11.7 T. After nearly 20 years of research and development, the magnet successfully reached its target field strength for the first time in 2019. This article reviews its commissioning status, the gradient-magnet interaction test results and first imaging experience. MATERIALS AND
methodsVibration, acoustics, power deposition in the He bath, and field monitoring measurements were carried out. Magnet safety system was tested against outer magnetic perturbations, and calibrated to define a safe operation of the gradient coil. First measurements using parallel transmission were also performed on an ex-vivo brain to mitigate the RF field inhomogeneity effect.
resultsAcoustics measurements show promising results with sound pressure levels slightly above the enforced limits only at certain frequency intervals. Vibrations of the gradient coil revealed a linear trend with the B DISCUSSION: Gradient-magnet interaction tests at up to 11.7 T are concluded. The scanner is now kept permanently at field and the final calibrations are on-going to pave the road towards the first acquisitions on volunteers.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.