Evidence map›Paper›PMID 36715884›Full record

ReviewMagma (New York, N.Y.)2023

Commissioning of the Iseult CEA 11.7 T whole-body MRI: current status, gradient-magnet interaction tests and first imaging experience.

Nicolas Boulant, Lionel Quettier, Iseult Consortium

Abstract readReview
In one paragraph

Review in Magma (New York, N.Y.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed.

  1. Article
  2. Magnetic resonance imaging.Science advances · 2026
    Review
  3. Low-AC-Loss Nb3Sn Validation Model Coil in Solid Nitrogen for a Fast-Switching-Field MRI Magnet Prototype.IEEE transactions on applied superconductivity : a publication of the IEEE Superconductivity Committee · 2026
    Article
  4. Motion- and Field-Robust Mesoscopic Whole-BrainMagnetic resonance in medicine · 2026
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Quo Vadis MRI?Zeitschrift fur medizinische Physik · 2025
    Article
  12. Article
  13. Article
  14. Article
  15. Acoustic noise reduction in the NexGen 7 T scanner.Magnetic resonance in medicine · 2024
    Article
  16. Article
  17. AC Loss Measurement in NbIEEE transactions on applied superconductivity : a publication of the IEEE Superconductivity Committee · 2024
    Article
  18. Review
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Nicolas BoulantUniversité Paris-Saclay, CEA, CNRS, BAOBAB, NeuroSpin, Gif Sur Yvette, France. nicolas.boulant@cea.fr.ORCID http://orcid.org/0000-0003-2144-2484
Lionel QuettierUniversité Paris-Saclay, CEA, Irfu, Département des Accélérateurs, de la Cryogénie et du Magnétisme, Gif Sur Yvette, France.
Iseult Consortium

Funding

H2020 Future and Emerging Technologies 885876
6 · The paper itself

Abstract

objectivesThe Iseult MRI is an actively shielded whole-body magnet providing a homogeneous and stable magnetic field of 11.7 T. After nearly 20 years of research and development, the magnet successfully reached its target field strength for the first time in 2019. This article reviews its commissioning status, the gradient-magnet interaction test results and first imaging experience. MATERIALS AND

methodsVibration, acoustics, power deposition in the He bath, and field monitoring measurements were carried out. Magnet safety system was tested against outer magnetic perturbations, and calibrated to define a safe operation of the gradient coil. First measurements using parallel transmission were also performed on an ex-vivo brain to mitigate the RF field inhomogeneity effect.

resultsAcoustics measurements show promising results with sound pressure levels slightly above the enforced limits only at certain frequency intervals. Vibrations of the gradient coil revealed a linear trend with the B DISCUSSION: Gradient-magnet interaction tests at up to 11.7 T are concluded. The scanner is now kept permanently at field and the final calibrations are on-going to pave the road towards the first acquisitions on volunteers.

Indexed as

Magnetic Resonance ImagingMagnetsHumansMagnetic FieldsMagneticsWhole Body ImagingGradient-magnet interactionsMRIUltra-high field

Identifiers

PMID36715884
PMCPMC10140097

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.