Evidence map›Paper›PMID 36713988›Full record

ArticleEuropean heart journal. Digital health2022

Clinical validation of an artificial intelligence-assisted algorithm for automated quantification of left ventricular ejection fraction in real time by a novel handheld ultrasound device.

Stella-Lida Papadopoulou, Vasileios Sachpekidis, Vasiliki Kantartzi, Ioannis Styliadis, Petros Nihoyannopoulos

Open access · goldAbstract read
In one paragraph

Article in European heart journal. Digital health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed, 1 pooled it
5.0field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 1 synthesis or guideline pooled it, 34 citations in OpenAlex.

  1. Guideline
  2. Trial
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Article
  12. Review
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Stella-Lida PapadopoulouDepartment of Cardiology, Papageorgiou General Hospital, Ring Road, Nea Efkarpia, Thessaloniki 56403, Greece.ORCID https://orcid.org/0000-0002-6577-0407
Vasileios SachpekidisDepartment of Cardiology, Papageorgiou General Hospital, Ring Road, Nea Efkarpia, Thessaloniki 56403, Greece.
Vasiliki KantartziDepartment of Cardiology, Papageorgiou General Hospital, Ring Road, Nea Efkarpia, Thessaloniki 56403, Greece.
Ioannis StyliadisDepartment of Cardiology, Papageorgiou General Hospital, Ring Road, Nea Efkarpia, Thessaloniki 56403, Greece.
Petros NihoyannopoulosImperial College London, National Heart & Lung Institute, The Hammersmith Hospital, Du Cane Road, London W120NN, UK.
Papageorgiou General Hospital · GRNational and Kapodistrian University of Athens · GR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aims: We sought to evaluate the reliability and diagnostic accuracy of a novel handheld ultrasound device (HUD) with artificial intelligence (AI) assisted algorithm to automatically calculate ejection fraction (autoEF) in a real-world patient population. Methods and results: We studied 100 consecutive patients (57 ± 15 years old, 61% male), including 38 with abnormal left ventricular (LV) function [LV ejection fraction (LVEF) < 50%]. The autoEF results acquired using the HUD were independently compared with manually traced biplane Simpson's rule measurements on cart-based systems to assess method agreement using intra-class correlation coefficient (ICC), linear regression analysis, and Bland-Altman analysis. The diagnostic accuracy for the detection of LVEF <50% was also calculated. Test-retest reliability of measured EF by the HUD was assessed by calculating the ICC and the minimal detectable change (MDC). The ICC, linear regression analysis, and Bland-Altman analysis revealed good agreement between autoEF and reference manual EF (ICC = 0.85; Conclusion: Use of a novel HUD with AI-enabled capabilities provided similar LVEF results with those derived by manual biplane Simpson's method on cart-based systems and shows clinical potential.

Indexed as

Artificial intelligenceAutomatedEchocardiographyEjection fractionHandheld ultrasound deviceLeft ventricular function

Identifiers

PMID36713988
PMCPMC9707920
OpenAlexW4205593347

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.