Evidence map›Paper›PMID 36713041›Full record

ArticleHeart rhythm O22023

Exploratory use of intraprocedural transesophageal echocardiography to guide implantation of the leadless pacemaker.

Bashaer Gheyath, Roshni Vijay Khatiwala, Shaomin Chen, Zhifan Fu, Neil Beri, Carter English, Heejung Bang, Uma Srivatsa, Nayereh Pezeshkian, Kwame Atsina and 1 more

Abstract read
In one paragraph

Article in Heart rhythm O2, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Trial
  2. Article
  3. Transesophageal echocardiography versus fluoroscopy-guided left bundle branch area pacing: a comparative study.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Bashaer GheyathDivision of Cardiovascular Medicine, Department of Internal Medicine, University of California Davis, Sacramento, California.
Roshni Vijay KhatiwalaDivision of Cardiovascular Medicine, Department of Internal Medicine, University of California Davis, Sacramento, California.
Shaomin ChenDepartment of Cardiology and Institute of Vascular Medicine, Peking University Third Hospital, Beijing, China.
Zhifan FuDepartment of Geriartics, Peking University First Hospital, Beijing, China.
Neil BeriDivision of Cardiovascular Medicine, Department of Internal Medicine, University of California Davis, Sacramento, California.
Carter EnglishDivision of Cardiovascular Medicine, Department of Internal Medicine, University of California Davis, Sacramento, California.
Heejung BangDivision of Biostatistics, Department of Public Health Sciences, University of California Davis, Sacramento, California.
Uma SrivatsaDivision of Cardiovascular Medicine, Department of Internal Medicine, University of California Davis, Sacramento, California.
Nayereh PezeshkianDivision of Cardiovascular Medicine, Department of Internal Medicine, University of California Davis, Sacramento, California.
Kwame AtsinaDivision of Cardiovascular Medicine, Department of Internal Medicine, University of California Davis, Sacramento, California.
Dali FanDivision of Cardiovascular Medicine, Department of Internal Medicine, University of California Davis, Sacramento, California.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Fluoroscopy is the standard tool for transvenous implantation of traditional and leadless pacemakers (LPs). LPs are used to avoid complications of conventional pacemakers, but there still is a 6.5% risk of major complications. Mid-right ventricular (RV) septal device implantation is suggested to decrease the risk, but helpful cardiac landmarks cannot be visualized under fluoroscopy. Transesophageal echocardiography (TEE) is an alternative intraprocedural imaging method. Objective: The purpose of this study was to explore the spatial relationship of the LP to cardiac landmarks via TEE and their correlations with electrocardiographic (ECG) parameters, and to outline an intraprocedural method to confirm mid-RV nonapical lead positioning. Methods: Fifty-six patients undergoing implantation of LP with TEE guidance were enrolled in the study. Device position was evaluated by fluoroscopy, ECG, and TEE. Distances between the device and cardiac landmarks were measured by TEE and analyzed with ECG parameters with and without RV pacing. Results: Mid-RV septal positioning was achieved in all patients. TEE transgastric view (0°-40°/90°-130°) was the optimal view for visualizing device position. Mean tricuspid valve-LP distance was 4.9 ± 0.9 cm, mean pulmonary valve-LP distance was 4.2 ± 1 cm, and calculated RV apex-LP distance was 2.9 ± 1 cm. Mean LP paced QRS width was 160.8 ± 28 ms and increased from 117.2 ± 34 ms at baseline. LP RV pacing resulted in left bundle branch block pattern on ECG and 37.8% QRS widening by 43.5 ± 29 ms. Conclusion: TEE may guide LP implantation in the nonapical mid-RV position. Further studies are required to establish whether this technique reduces implant complications compared with conventional fluoroscopy.

Indexed as

Intraprocedural imagingLeadless pacemakerNonfluoroscopic imagingSeptal pacingTransesophageal echocardiography

Identifiers

PMID36713041
PMCPMC9877395

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.