Evidence map›Paper›PMID 36713039›Full record

ArticleHeart rhythm O22023

An ensemble of features based deep learning neural network for reduction of inappropriate atrial fibrillation detection in implantable cardiac monitors.

Shantanu Sarkar, Shubha Majumder, Jodi L Koehler, Sean R Landman

Open access · goldAbstract read
In one paragraph

Article in Heart rhythm O2, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.0field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. State of the Art of Artificial Intelligence in Clinical Electrophysiology in 2025: A Scientific Statement of the European Heart Rhythm Association (EHRA) of the ESC, the Heart Rhythm Society (HRS), and the ESC Working Group on E-Cardiology.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Shantanu SarkarMedtronic Inc, Minneapolis, Minnesota.
Shubha MajumderMedtronic Inc, Minneapolis, Minnesota.
Jodi L KoehlerMedtronic Inc, Minneapolis, Minnesota.
Sean R LandmanMedtronic Inc, Minneapolis, Minnesota.
Medtronic (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Multiple studies have reported on classification of raw electrocardiograms (ECGs) using convolutional neural networks (CNNs). Objective: We investigated an application-specific CNN using a custom ensemble of features designed based on characteristics of the ECG during atrial fibrillation (AF) to reduce inappropriate AF detections in implantable cardiac monitors (ICMs). Methods: An ensemble of features was developed and combined to form an input signal for the CNN. The features were based on the morphological characteristics of AF, incoherence of RR intervals, and the fact that AF begets more AF. A custom CNN model and the RESNET18 model were trained using ICM-detected AF episodes that were adjudicated to be true AF or false detections. The trained models were evaluated using a test dataset from independent patients. Results: The training and validation datasets consisted of 31,757 AF episodes (2516 patients) and 28,506 false episodes (2126 patients). The validation set (20% randomly chosen episodes of each type) had an area under the curve of 0.996 for custom CNN (0.993 for RESNET18). Thresholds were chosen to obtain a relative sensitivity and specificity of 99.2% and 92.8%, respectively (99.2% and 87.9% for RESNET18, respectively). The performance in the independent test set (4546 AF episodes from 418 patients; 5384 false episodes from 605 patients) showed an area under the curve of 0.993 (0.991 for RESNET18) and relative sensitivity and specificity of 98.7% and 91.4%, respectively, at chosen thresholds (98.9% and 88.2% for RESNET18, respectively). Conclusion: An ensemble of features-based CNNs was developed that reduced inappropriate AF detection in ICMs by over 90% while preserving sensitivity.

Indexed as

Artificial intelligenceAtrial fibrillationConvolutional neural networksDeep learningElectrocardiogramImplantable cardiac monitorsResidual neural network

Identifiers

PMID36713039
PMCPMC9877397
OpenAlexW4307742794

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.