Evidence map›Paper›PMID 36709744›Full record

ArticleInternational journal of hygiene and environmental health2023

Estimating the restraint of SARS-CoV-2 spread using a conventional medical air-cleaning device: Based on an experiment in a typical dental clinical setting.

Zhijian Liu, Peiwen Zhang, Haiyang Liu, Junzhou He, Yabin Li, Guangpeng Yao, Jia Liu, Meng Lv, Wenhui Yang

Open access · greenAbstract read
In one paragraph

Article in International journal of hygiene and environmental health, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Zhijian LiuDepartment of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China. Electronic address: zhijianliu@ncepu.edu.cn.
Peiwen ZhangDepartment of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China.
Haiyang LiuDepartment of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China.
Junzhou HeDepartment of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China.
Yabin LiThe Fifth Medical Center of People's Liberation Army of China General Hospital, Beijing, 100039, China.
Guangpeng YaoDepartment of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China.
Jia LiuThe Fifth Medical Center of People's Liberation Army of China General Hospital, Beijing, 100039, China.
Meng LvState Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, China.
Wenhui YangState Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, China. Electronic address: fionyoung@163.com.
North China Electric Power University · CNInstitute of Microbiology · CNPeople's Liberation Army No. 150 Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesDroplets or aerosols loaded with SARS-CoV-2 can be released during breathing, coughing, or sneezing from COVID-19-infected persons. To investigate whether the most commonly applied air-cleaning device in dental clinics, the oral spray suction machine (OSSM), can provide protection to healthcare providers working in clinics against exposure to bioaerosols during dental treatment.

methodIn this study, we measured and characterized the temporal and spatial variations in bioaerosol concentration and deposition with and without the use of the OSSM using an experimental design in a dental clinic setting. Serratia marcescens (a bacterium) and ΦX174 phage (a virus) were used as tracers. The air sampling points were sampled using an Anderson six-stage sampler, and the surface-deposition sampling points were sampled using the natural sedimentation method. The Computational Fluid Dynamics method was adopted to simulate and visualize the effect of the OSSM on the concentration spatial distribution.

resultsDuring dental treatment, the peak exposure concentration increased by up to 2-3 orders of magnitude (PFU/m

conclusionThe use of OSSM showed the potential to restraint the spread of bioaerosols in clinical settings. Our study demonstrates that OSSM use in dental clinics can reduce the exposure concentrations of bioaerosols for healthcare workers during dental treatment and is beneficial for minimizing the risk of infectious diseases such as COVID-19.

Indexed as

COVID-19SARS-CoV-2Air MicrobiologyBacteriaHumansRespiratory Aerosols and DropletsAir-cleaning deviceBioaerosolCOVID-19Dental clinicHealthcare workers

Identifiers

PMID36709744
PMCPMC9883001
OpenAlexW4318203673

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked