Evidence map›Paper›PMID 36709374›Full record

ArticleScientific reports2023

An urgent health problem of indoor air pollution: results from a 15-years carbon monoxide poisoning observed study in Jinan City.

Mingjun Li, Bing Shan, Xiumiao Peng, Huiyun Chang, Liangliang Cui

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.5field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Mingjun LiDepartment of Research and Education, Jinan Municipal Center for Disease Control and Prevention, Jinan Municipal Center for Disease Control and Prevention Affiliated to Shandong University, 2 Weiliu Road, Huaiyin District, 250021, Jinan, China.
Bing ShanDepartment of Environmental Health, Jinan Municipal Center for Disease Control and Prevention, Jinan Municipal Center for Disease Control and Prevention Affiliated to Shandong University, 2 Weiliu Road, Huaiyin District, Jinan, 250021, China.
Xiumiao PengDepartment of Environmental Health, Jinan Municipal Center for Disease Control and Prevention, Jinan Municipal Center for Disease Control and Prevention Affiliated to Shandong University, 2 Weiliu Road, Huaiyin District, Jinan, 250021, China.
Huiyun ChangDepartment of Research and Education, Jinan Municipal Center for Disease Control and Prevention, Jinan Municipal Center for Disease Control and Prevention Affiliated to Shandong University, 2 Weiliu Road, Huaiyin District, 250021, Jinan, China.
Liangliang CuiDepartment of Research and Education, Jinan Municipal Center for Disease Control and Prevention, Jinan Municipal Center for Disease Control and Prevention Affiliated to Shandong University, 2 Weiliu Road, Huaiyin District, 250021, Jinan, China. cll602@163.com.
Shandong University · CNShandong Center for Disease Control and Prevention · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Carbon monoxide (CO) poisoning is a public health concern in developing countries especially in China with a high disease burden. We aimed to focus on non-occupational CO poisoning caused by household coal heating secular trends based on registry data in Jinan, China, and we aim to provide further evidence and suggestions for public health policy. We analyzed the occurrence and development trend and assess the spatial-temporal epidemiological characteristics of non-occupational CO poisoning caused by household coal heating in Jinan between 2007 and 2021. Among total of 6588 CO poisoning, 5616 cases (85.25%) and 180 deaths caused by household coal heating was identified during study period. The cumulative incidence rate was 5.78 per 100,000 person-years and the mortality rate was 0.19 per 100,000 person-years. The incidence in urban areas (6.55 per 100,000 person-years) was higher than rural areas (5.04 per 100,000 person-years), and there was a statistical difference between urban and rural (P < 0.001) (P < 0.001). The poisoning time point mainly occurs in the sleep stage. In Jinan, socioeconomic status, accessibility to health services and rural status are determinants for CO poisoning incidence and mortality. Implementation of urban and rural central heating renovation is an effective way to further reduce the disease burden of CO poisoning in the future.

Indexed as

Air PollutionAir Pollution, IndoorCarbon Monoxide PoisoningCarbon MonoxideChinaCitiesCoalHumansCarbon MonoxideCoal

Identifiers

PMID36709374
PMCPMC9884191
OpenAlexW4318344478

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.