Evidence map›Paper›PMID 36708203›Full record

ArticleMagnetic resonance in medicine2023

High-resolution motion- and phase-corrected functional MRI at 7 T using shuttered multishot echo-planar imaging.

Saikat Sengupta, Avery Berman, Jonathan R Polimeni, Kawin Setsompop, William A Grissom

Open access · bronzeAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.5field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 2 countries.

Saikat SenguptaVanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee, USA.ORCID 0000-0001-5032-006X
Avery BermanDepartment of Physics, Carleton University, Ottawa, Ontario, Canada.ORCID 0000-0001-7631-1049
Jonathan R PolimeniAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Kawin SetsompopRadiology, Stanford University, Stanford, California, USA.
William A GrissomVanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee, USA.ORCID 0000-0002-3289-1827
Vanderbilt University · USHarvard University · USUniversity of Ottawa · CAUniversity Radiology · US

Funding

MRI CORTICOGRAPHY: DEVELOPING NEXT GENERATION MICROSCALE HUMAN CORTEX MRI SCANNERU01EB025162 · NIBIB · UNIVERSITY OF CALIFORNIA BERKELEY · PI FEINBERG, DAVID ALAN, LIU, CHUNLEI · 2017 to 2021
$13.4M
Project 4U19NS123717 · NINDS · BOSTON UNIVERSITY (CHARLES RIVER CAMPUS) · PI KLEINFELD, DAVID · 2021 to 2025
$13.4M
fMRI Technologies for Imaging at the Limit of Biological Spatiotemporal Resolution: Administrative SupplementR01EB019437 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI POLIMENI, JONATHAN RIZZO, SETSOMPOP, KAWIN · 2015 to 2024
$5.5M
Improving Human fMRI through Modeling and Imaging Microvascular Dynamics: Administrative SupplementR01MH111419 · NIMH · MASSACHUSETTS GENERAL HOSPITAL · PI POLIMENI, JONATHAN RIZZO · 2016 to 2020
$4.9M
Three-Dimensional Patient-Tailored RF Pulses for Spin Echo Neuroimaging at 7 TR01EB016695 · NIBIB · VANDERBILT UNIVERSITY · PI GRISSOM, WILLIAM A · 2014 to 2021
$3.8M
NIBIB NIH HHS R01 EB016695NIBIB NIH HHS R01 EB019437NIBIB NIH HHS U01 EB025162NIMH NIH HHS R01 MH111419NINDS NIH HHS U19 NS123717
6 · The paper itself

Abstract

purposeTo achieve high-resolution multishot echo-planar imaging (EPI) for functional MRI (fMRI) with reduced sensitivity to in-plane motion and between-shot phase variations.

methodsTwo-dimensional radiofrequency pulses were incorporated in a multishot EPI sequence at 7T which selectively excited a set of in-plane bands (shutters) in the phase encoding direction, which moved between shots to cover the entire slice. A phase- and motion-corrected reconstruction was implemented for the acquisition. Brain imaging experiments were performed with instructed motion to evaluate image quality for conventional multishot and shuttered EPI. Temporal stability was assessed in three subjects by quantifying temporal SNR (tSNR) and artifact levels, and fMRI activation experiments using visual stimulation were performed to assess the strength and distribution of activation, using both conventional multishot and shuttered EPI.

resultsIn the instructed motion experiment, ghosting was lower in shuttered EPI images without or with corrections and image quality metrics were improved with motion correction. tSNR was improved by phase correction in both conventional multishot and shuttered EPI and the acquisitions had similar tSNR without and with phase correction. However, while phase correction was necessary to maximize tSNR in conventional multishot EPI, it also increased intermittent ghosting, but did not increase intermittent ghosting in shuttered EPI. Phase correction increased activation strength in both conventional multishot and shuttered EPI, but caused increased spurious activation outside the brain and in frontal brain regions in conventional multishot EPI.

conclusionShuttered EPI supports multishot segmented EPI acquisitions with lower sensitivity to artifacts from motion for high-resolution fMRI.

Indexed as

AlgorithmsEcho-Planar ImagingArtifactsBrainHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingMotion2D RFBOLDfMRIGRAPPAhigh spatial resolutionimage reconstructionmultishot EPIRF pulse designsegmented EPIultrahigh field

Identifiers

PMID36708203
PMCPMC10259881
OpenAlexW4318334537

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.