Evidence map›Paper›PMID 36708111›Full record

ArticleZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery2023

[Application of artificial intelligence preoperative planning system in total hip arthroplasty for adult developmental dysplasia of the hip].

Mieradili Maimaitiyiming, Yilihamujiang Wusiman, Rongxin Sun, Aierxiding Abulaiti

Open access · greenAbstract readEnglish Abstract
In one paragraph

Article in Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Mieradili MaimaitiyimingDepartment of Joint Surgery, the Sixth Affiliated Hospital of Xinjiang Medical University, Urumqi Xinjiang, 830002, P. R. China.
Yilihamujiang WusimanDepartment of Joint Surgery, the Sixth Affiliated Hospital of Xinjiang Medical University, Urumqi Xinjiang, 830002, P. R. China.
Rongxin SunDepartment of Joint Surgery, the Sixth Affiliated Hospital of Xinjiang Medical University, Urumqi Xinjiang, 830002, P. R. China.
Aierxiding AbulaitiDepartment of Joint Surgery, the Sixth Affiliated Hospital of Xinjiang Medical University, Urumqi Xinjiang, 830002, P. R. China.
Xinjiang Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: By comparing with the traditional X-ray template measurement method, to explore the accuracy of artificial intelligence preoperative planning system (AI-HIP) to predict the type of prosthesis and guide the placement of prosthesis before total hip arthroplasty (THA) in adult patients with developmental dysplasia of the hip (DDH). Methods: Patients with DDH scheduled for initial THA between August 2020 and August 2022 were enrolled as study object, of which 28 cases (28 hips) met the selection criteria were enrolled in the study. Among them, there were 10 males and 18 females, aged from 34 to 77 years, with an average of 59.3 years. There were 12 cases of the left DDH and 16 cases of the right DDH. According to DDH classification, there were 10 cases of Crowe type Ⅰ, 8 cases of type Ⅱ, 5 cases of type Ⅲ, and 5 cases of type Ⅳ. According to Association Research Circulation Osseous (ARCO) staging of osteonecrosis of the femoral head, 13 cases were in stage Ⅲ and 15 cases in stage Ⅳ. The disease duration was 2.5-23.0 years (mean, 8.6 years). The limb length discrepancy (LLD) was 11.0 (8.0, 17.5) mm. Before operation, the prosthesis types of all patients were predicted by AI-HIP system and X-ray template measurement method, respectively. And the preoperative results were compared with the actual prosthesis type during operation in order to estimate the accuracy of the AI-HIP system. Then, the differences in the acetabular abduction angle, acetabular anteversion angle, femoral neck osteotomy position, tip-shoulder distance, and LLD were compared between preoperative planned measurements by AI-HIP system and actual measurement results after operation, in order to investigate the ability of AI-HIP system to evaluate the placement position of prosthesis. Results: The types of acetabular and femoral prostheses predicted based on AI-HIP system before operation were consistent with the actual prostheses in 23 cases (82.1%) and 24 cases (85.7%), respectively. The types of acetabular and femoral prostheses predicted based on X-ray template measurement before operation were consistent with the actual prostheses in 16 cases (57.1%) and 17 cases (60.7%), respectively. There were significant differences between AI-HIP system and X-ray template measurement ( Conclusion: Compared with the traditional X-ray template measurement method, the preoperative planning of AI-HIP system has better accuracy and repeatability in predicting the prosthesis type. It has a certain reference for the prosthesis placement of adult DDH.

Indexed as

Arthroplasty, Replacement, HipDevelopmental Dysplasia of the HipHip Dislocation, CongenitalAdultAgedArtificial IntelligenceFemaleHumansMaleMiddle AgedRetrospective StudiesTreatment OutcomeArtificial intelligencedevelopmental dysplasia of the hippreoperative planningtotal hip arthroplasty

Identifiers

PMID36708111
PMCPMC9883647
OpenAlexW4318392884

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.