Evidence map›Paper›PMID 36707701›Full record

ArticleScientific reports2023

Three-dimensional soft tissue landmark detection with marching cube algorithm.

Yoonjung Lee, Ji-Min Lee, Sun-Hyung Park, Yoon Jeong Choi, Sung-Hwan Choi, Jae Joon Hwang, Hyung-Seog Yu

Erratum issuedAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

Yoonjung LeeDepartment of Orthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
Ji-Min LeeDepartment of Orthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
Sun-Hyung ParkDepartment of Orthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
Yoon Jeong ChoiDepartment of Orthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
Sung-Hwan ChoiDepartment of Orthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea. selfexam@yuhs.ac.
Jae Joon HwangDepartment of Oral and Maxillofacial Radiology, School of Dentistry, Dental Research Institute, Pusan National University, Yangsan, 50610, Republic of Korea. softdent@pusan.ac.kr.
Hyung-Seog YuDepartment of Orthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea. yumichael@yuhs.ac.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Current method of analyzing three-dimensional soft tissue data, especially in the frontal view, is subjective and has poor reliability. To overcome this limitation, the present study aimed to introduce a new method of analyzing soft tissue data reconstructed by marching cube algorithm (Program S) and compare it with a commercially available program (Program A). Cone-beam computed tomography images of 42 patients were included. Two orthodontists digitized six landmarks (pronasale, columella, upper and lower lip, right and left cheek) twice using both programs in two-week intervals, and the reliability was compared. Furthermore, computer-calculated point (CC point) was developed to evaluate whether human error could be reduced. The results showed that the intra- and inter-examiner reliability of Program S (99.7-100% and 99.9-100%, respectively) were higher than that of Program A (64.0-99.9% and 76.1-99.9%, respectively). Moreover, the inter-examiner difference of coordinate values and distances for all six landmarks in Program S was lower than Program A. Lastly, CC point was provided as a consistent single point. Therefore, it was validated that this new methodology can increase the intra- and inter-examiner reliability of soft tissue landmark digitation and CC point can be used as a landmark to reduce human error.

Indexed as

AlgorithmsImaging, Three-DimensionalCephalometryCone-Beam Computed TomographyHumansLipReproducibility of Results

Identifiers

PMID36707701
PMCPMC9883223

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.