Evidence map›Paper›PMID 36707671›Full record

ArticleScientific reports2023

Low-volume label-free SARS-CoV-2 detection with the microcavity-based optical fiber sensor.

Monika Janik, Tomasz Gabler, Marcin Koba, Mirosława Panasiuk, Yanina Dashkevich, Tomasz Łęga, Agnieszka Dąbrowska, Antonina Naskalska, Sabina Żołędowska, Dawid Nidzworski and 3 more

Abstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Monika JanikInstitute of Microelectronics and Optoelectronics, Warsaw University of Technology, Koszykowa 75, 00-662, Warszawa, Poland. monika.janik@pw.edu.pl.
Tomasz GablerInstitute of Microelectronics and Optoelectronics, Warsaw University of Technology, Koszykowa 75, 00-662, Warszawa, Poland.
Marcin KobaInstitute of Microelectronics and Optoelectronics, Warsaw University of Technology, Koszykowa 75, 00-662, Warszawa, Poland.
Mirosława PanasiukInstitute of Biotechnology and Molecular Medicine, Kampinoska 25, 80-180, Gdańsk, Poland.
Yanina DashkevichInstitute of Biotechnology and Molecular Medicine, Kampinoska 25, 80-180, Gdańsk, Poland.
Tomasz ŁęgaInstitute of Biotechnology and Molecular Medicine, Kampinoska 25, 80-180, Gdańsk, Poland.
Agnieszka DąbrowskaVirogenetics Laboratory of Virology, Malopolska Centre of Biotechnology, Jagiellonian University, Gronostajowa 7a, 30-387, Krakow, Poland.
Antonina NaskalskaVirogenetics Laboratory of Virology, Malopolska Centre of Biotechnology, Jagiellonian University, Gronostajowa 7a, 30-387, Krakow, Poland.
Sabina ŻołędowskaInstitute of Biotechnology and Molecular Medicine, Kampinoska 25, 80-180, Gdańsk, Poland.
Dawid NidzworskiInstitute of Biotechnology and Molecular Medicine, Kampinoska 25, 80-180, Gdańsk, Poland.
Krzysztof PyrćVirogenetics Laboratory of Virology, Malopolska Centre of Biotechnology, Jagiellonian University, Gronostajowa 7a, 30-387, Krakow, Poland.
Beata GromadzkaInstitute of Biotechnology and Molecular Medicine, Kampinoska 25, 80-180, Gdańsk, Poland.
Mateusz ŚmietanaInstitute of Microelectronics and Optoelectronics, Warsaw University of Technology, Koszykowa 75, 00-662, Warszawa, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate and fast detection of viruses is crucial for controlling outbreaks of many diseases; therefore, to date, numerous sensing systems for their detection have been studied. On top of the performance of these sensing systems, the availability of biorecognition elements specific to especially the new etiological agents is an additional fundamental challenge. Therefore, besides high sensitivity and selectivity, such advantages as the size of the sensor and possibly low volume of analyzed samples are also important, especially at the stage of evaluating the receptor-target interactions in the case of new etiological agents when typically, only tiny amounts of the receptor are available for testing. This work introduces a real-time, highly miniaturized sensing solution based on microcavity in-line Mach-Zehnder interferometer (μIMZI) induced in optical fiber for SARS-CoV-2 virus-like particles detection. The assay is designed to detect conserved regions of the SARS-CoV-2 viral particles in a sample with a volume as small as hundreds of picoliters, reaching the detection limit at the single ng per mL level.

Indexed as

Biosensing TechniquesCOVID-19HumansInterferometryOptical FibersSARS-CoV-2

Identifiers

PMID36707671
PMCPMC9880943

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.