Evidence map›Paper›PMID 36707432›Full record

ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2023

Audiological outcome after stapes surgery in relation to prosthesis type.

Vanessa Handke, Parwis Agha-Mir-Salim, Paul James, Alexander Müller

Open access · hybridAbstract read
In one paragraph

Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Clinical outcomes of 188 patients implanted with Med-El stapes prostheses.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
    Article
  3. Article
  4. Investigation of the coupling quality of partial prostheses at the stapes head.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Vanessa HandkeDepartment of Otorhinolaryngology, Head, Neck, Plastic and Cosmetic Surgery, Friedrichshain Clinic, Vivantes Hearing Center (HZB), Landsberger Allee 49, 10249, Berlin, Germany. vanessa.handke@vivantes.de.ORCID http://orcid.org/0000-0002-3435-1672
Parwis Agha-Mir-SalimDepartment of Otorhinolaryngology, Head, Neck, Plastic and Cosmetic Surgery, Friedrichshain Clinic, Vivantes Hearing Center (HZB), Landsberger Allee 49, 10249, Berlin, Germany.
Paul JamesDepartment of Otorhinolaryngology, Head and Neck Surgery and Communication Disorders, HELIOS-Clinic Berlin-Buch, Berlin, Germany.
Alexander MüllerDepartment of Otorhinolaryngology, Head, Neck, Plastic and Cosmetic Surgery, Friedrichshain Clinic, Vivantes Hearing Center (HZB), Landsberger Allee 49, 10249, Berlin, Germany.
Klinikum im Friedrichshain · DEHelios Hospital Berlin-Buch · DEVivantes Klinikum · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDifferent techniques are used to fix crimp and CliP® Piston stapes prostheses to the long process of the incus (LPI). The CliP® Piston provides a stiff connection in contrast to the static bended loop of the crimp prosthesis, which imitates the physiological incudostapedial joint (ISJ) and thereby potentially leads to different hearing outcome.

methodsIn a retrospective single-center study of German-speaking one hundred and ninety patients who underwent stapes surgery CliP® Piston or crimp prostheses between the years of 2016 and 2019 by the same surgeon and in the same setting. Pre- and postoperative bone- (BC) and air-conduction (AC) pure-tone thresholds, pre- and postoperative air-bone gap (ABG) for 0.5, 1, 1.5, 2, 3, 4 kHz and the surgery time were examined.

resultsThe postoperative bone conduction thresholds were significantly lower in the frequencies between 0.5 and 3 kHz and the mean ABG was < 10 dB in most cases independent of the prosthesis used. Crimp prosthesis showed a significantly better closure of the ABG at 0.5 kHz.

conclusionsThe audiological outcome after stapes surgery is dependent on the type of prosthesis used, as reflected by the frequency-specific air-bone gap. The better ABG closure with the crimp prosthesis might be the result of the connection to the LPI imitating the physiological ISJ. The crimp prosthesis may be the better choice if use of hearing aids is expected postoperatively.

Indexed as

Ossicular ProsthesisOtosclerosisStapes SurgeryBone ConductionHearingHumansProsthesis ImplantationRetrospective StudiesStapesTreatment OutcomeAir–bone gapAudiological outcomeProsthesis typeStapes surgerySurgery time

Identifiers

PMID36707432
PMCPMC10220147
OpenAlexW4318321234

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.