Evidence map›Paper›PMID 36704243›Full record

ArticleIEEE journal of translational engineering in health and medicine2023

Using Inertial Measurement Unit Sensor Single Axis Rotation Angles for Knee and Hip Flexion Angle Calculations During Gait.

Nuno Oliveira, Joonsun Park, Peter Barrance

Open access · goldAbstract read
In one paragraph

Article in IEEE journal of translational engineering in health and medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
4.3field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 10 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 1 country.

Nuno OliveiraSchool of Kinesiology and NutritionThe University of Southern Mississippi Hattiesburg MS 39402 USA.ORCID 0000-0002-1566-4171
Joonsun ParkDepartment of Kinesiology and Health ScienceUtah State University Logan UT 84322 USA.
Peter BarranceCenter for Mobility and Rehabilitation Engineering ResearchKessler Foundation West Orange NJ 07052 USA.ORCID 0000-0003-3203-0266
Rutgers, The State University of New Jersey · USUniversity of Southern Mississippi · USUtah State University · US

Funding

Tracking and Evaluation CoreU54GM115428 · NIGMS · UNIVERSITY OF MISSISSIPPI MED CTR · PI COMPRETTA, CAROLINE E. · 2016 to 2025
$38.2M
NIGMS NIH HHS U54 GM115428
6 · The paper itself

Abstract

backgroundHip and knee flexion joint motions are frequently examined in clinical practice using camera based motion capture (CBMC) systems; however, these systems require elaborate setups and dedicated space. Inertial measurement unit (IMU) based systems avoid these disadvantages but require validation before widespread adoption. Moreover, it is important for clinical practice to determine the stability of these systems for prolonged evaluation periods. The purpose of this study was to assess the validity of a three-sensor inertial measurement unit system for calculating hip and knee flexion angles during gait by comparing with a gold standard CBMC system. Validity was also examined before and after a treadmill walking session.

methodsTwenty healthy participants were tested. Twenty seconds of gait at preferred walking speed were analyzed before and after thirty-two minutes of treadmill walking using previously validated CBMC methods and with a custom IMU model. Measurement validity for the IMU system was evaluated using Bland & Altman 95 percent limits of agreement, linear regression, mean absolute error and root mean square error. The effects of a measurement zeroing calibration strategy were also investigated.

resultsStrong measurement agreement was observed for both hip and knee flexion angles, although overall agreement for the hip exceeded that for the knee. Linear regressions between the datasets for each participant illustrated strong (> 0.94) relationships between IMU and CBMC measurements. More significant changes between timepoints were observed for the knee than for the hip. Error values were generally reduced when zeroing calibration was implemented.

conclusionThe IMU system presented in this study is a convenient and accessible technique to measure joint angles. The protocol described in the current study can be easily applied in the clinical setting for evaluation of clinical populations. Additional development work on sensor placement and calibration methods may further increase the accuracy of such methods. Clinical translation statement: The IMU system presented in this study is a convenient and accessible technique to measure joint angles. Additional developmentwork on sensor placement and calibration methods may further increase the accuracy of such methods.

Indexed as

GaitKnee JointBiomechanical PhenomenaHumansKneeRotationGaithipinertial measurement unitskneevalidation

Identifiers

PMID36704243
PMCPMC9870263
OpenAlexW4312219225

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.