Evidence map›Paper›PMID 36703099›Full record

SynthesisBMC emergency medicine2023

Is it time to re-think FAST? A systematic review and meta-analysis of Contrast-Enhanced Ultrasound (CEUS) and conventional ultrasound for initial assessment of abdominal trauma.

Bayu Sutarjono, Matthew Kessel, Dorian Alexander, Ekjot Grewal

Open access · goldAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in BMC emergency medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
6.0field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it, 19 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Microbubble Contrast Agents Improve Detection of Active Hemorrhage.IEEE open journal of engineering in medicine and biology · 2024
    Article
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Bayu SutarjonoDepartment of Emergency Medicine, Brookdale University Hospital and Medical Center, 1 Brookdale Plaza, Brooklyn, NY, 11212, USA. b.sutarjono@saba.edu.
Matthew KesselDepartment of Emergency Medicine, Brookdale University Hospital and Medical Center, 1 Brookdale Plaza, Brooklyn, NY, 11212, USA.
Dorian AlexanderDepartment of Emergency Medicine, Brookdale University Hospital and Medical Center, 1 Brookdale Plaza, Brooklyn, NY, 11212, USA.
Ekjot GrewalDepartment of Emergency Medicine, Brookdale University Hospital and Medical Center, 1 Brookdale Plaza, Brooklyn, NY, 11212, USA.
Brookdale University Hospital and Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe Focused Assessment with Sonography for Trauma (FAST) examination using conventional ultrasound has limited utility for detecting solid organ injury. Therefore, this systematic review and meta-analysis compares the performance of contrast-enhanced ultrasound (CEUS) to conventional ultrasound when used as the initial assessment for abdominal trauma prior to computed tomography (CT) imaging.

methodsA systematic literature search of major databases was conducted of human studies investigating the diagnostic accuracy of conventional ultrasound and CEUS occurring prior to CT imaging for abdominal trauma. The study followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement. The quality of studies was evaluated using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) tool. Paired pooled sensitivity and specificity between conventional ultrasound and CEUS were compared using data extracted from the eligible studies. Diagnostic odds ratio, number needed to diagnose values, and likelihood ratios were also determined.

resultsTen studies were included. More than half of the included studies demonstrated low risk of bias. Using McNemar's test to assess for paired binary observations, we found that CEUS had statistically higher sensitivity (0.933 vs. 0.559; two-tailed, P < 0.001) and specificity (0.995 vs. 0.979; two-tailed, P < 0.001) than conventional ultrasound in the setting of abdominal trauma, respectively. When divided into particular findings of clinical interest, CEUS had statistically higher sensitivity than conventional ultrasound in screening for active bleeding and injuries to all abdominal solid organs. CEUS also had superior diagnostic odds ratios, number needed to diagnose values, and likelihood ratios than conventional ultrasound.

conclusionThe diagnostic value of CEUS was higher than that of conventional ultrasound for differentiating traumatic abdominal injuries when used as the initial assessment in the emergency department.

Indexed as

Abdominal InjuriesContrast MediaHumansSensitivity and SpecificityTomography, X-Ray ComputedUltrasonographyContrast MediaCEUSContrast-enhanced ultrasoundEmergency medicineTrauma

Identifiers

PMID36703099
PMCPMC9881326
OpenAlexW4318184342

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.