Evidence map›Paper›PMID 36699261›Full record

ArticleHeliyon2023

Square wave reference digital lock-in detection using non-orthogonal demodulation.

Miao Li, Yue Sun, Zhen Liang, Shengzhao Zhang

Abstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Miao LiSchool of Biomedical Engineering, Anhui Medical University, Hefei, 230032, China.
Yue SunSchool of Biomedical Engineering, Anhui Medical University, Hefei, 230032, China.
Zhen LiangSchool of Biomedical Engineering, Anhui Medical University, Hefei, 230032, China.
Shengzhao ZhangSchool of Biomedical Engineering, Anhui Medical University, Hefei, 230032, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Digital lock-in detection technique is commonly used to measure the amplitude and phase of a selected frequency signal. The technique which uses a square wave as the reference signal has an advantage of easier implementation and higher computational efficiency compared to that uses a sine wave. However, one constraint for a square wave reference digital lock-in is that the sampling rate must be the integral multiple of 4 of all the signal frequencies. As the sampling clock may not always be able to set to the integral multiple of 4 of the signal frequencies, the constraint brings inconvenient for the implementation. Presented in this paper is a novel algorithm for square wave digital lock-in detection in which the sampling frequency doesn't have to meet the constraint. The algorithm allows frequency sweep measurements with a fixed sampling rate. For different relationships between the sampling rate and the signal frequency, different calculation equations are provided in this paper. Simulations and actual experiments show the feasibility of the proposed algorithm.

Indexed as

Digital lock-in detectionNon-orthogonal demodulationSampling rateSquare wave-referenceWeak signal detection

Identifiers

PMID36699261
PMCPMC9868535

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.