Evidence map›Paper›PMID 36698656›Full record

ArticleBiomedical optics express2023

Voltage-modulated surface plasmon resonance biosensors integrated with gold nanohole arrays.

Syu-Cing Ma, Rohit Gupta, Neil Adrian P Ondevilla, Kuntal Barman, Liang-Yun Lee, Hsien-Chang Chang, Jian-Jang Huang

Abstract read
In one paragraph

Article in Biomedical optics express, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Research Progress on Nanomaterials in SPR Sensors.Nanomaterials (Basel, Switzerland) · 2025
    Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Syu-Cing MaGraduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei, Taiwan.
Rohit GuptaGraduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei, Taiwan.
Neil Adrian P OndevillaDepartment of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
Kuntal BarmanGraduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei, Taiwan.
Liang-Yun LeeGraduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei, Taiwan.
Hsien-Chang ChangDepartment of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
Jian-Jang HuangGraduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei, Taiwan.ORCID https://orcid.org/0000-0002-5761-2177

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Surface plasmon resonance (SPR) has emerged as one of the most efficient and attractive techniques for optical sensors in biological applications. The traditional approach of an EC (electrochemical)-SPR biosensor to generate SPR is by adopting a prism underneath the sensing substrate, and an angular scan is performed to characterize the reflectivity of target analytes. In this paper, we designed and investigated a novel optical biosensor based on a hybrid plasmonic and electrochemical phenomenon. The SPR was generated from a thin layer of gold nanohole array on a glass substrate. Using C-Reactive Protein (CRP) as the target analyte, we tested our device for different concentrations and observed the optical response under various voltage bias conditions. We observed that SPR response is concentration-dependent and can be modulated by varying DC voltages or AC bias frequencies. For CRP concentrations ranging from 1 to 1000 µg/mL, at the applied voltage of -600 mV, we obtained a limit of detection for this device of 16.5 ng/mL at the resonance peak wavelength of 690 nm. The phenomenon is due to spatial re-distribution of electron concentration at the metal-solution interface. The results suggest that CRP concentration can be determined from the SPR peak wavelength shift by scanning the voltages. The proposed new sensor structure is permissible for various future optoelectronic integration for plasmonic and electrochemical sensing.

Identifiers

PMID36698656
PMCPMC9842002

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.