Evidence map›Paper›PMID 36696049›Full record

ArticleBiomechanics and modeling in mechanobiology2023

Porous metal block based on topology optimization to treat distal femoral bone defect in total knee revision.

Jiangbo Zhang, Aobo Zhang, Qing Han, Yang Liu, Hao Chen, Mingyue Ma, Yongyue Li, Bingpeng Chen, Jincheng Wang

Abstract read
In one paragraph

Article in Biomechanics and modeling in mechanobiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jiangbo Zhang *Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China.
Aobo ZhangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China.
Qing Han *Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China.
Yang LiuDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China.
Hao ChenDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China.
Mingyue MaDepartment of Breast Surgery, The First Hospital of Jilin University, Changchun, 130021, China.
Yongyue LiDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China.
Bingpeng ChenDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China. 53495365@qq.com.
Jincheng WangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China.

Funding

Bethune plan of Jilin University 470110000692Department of finance in Jilin province 2020SCZT037Department of Science and Technology of Jilin Province 20200201453JCDepartment of Science and Technology of Jilin Province 20200403086SFDepartment of Science and Technology of Jilin Province 20200404202YYGraduate Innovation Fund of Jilin University 101832020CX296Jilin Province Development and Reform Commission 2018C010Key training plan for outstanding young teachers of Jilin University 419080520253National Key Research and Development Program of China 2018YFB1105100National Natural Science Foundation of China 82072456Undergraduate teaching reform research project of Jilin University 4Z2000610852
6 · The paper itself

Abstract

Metal block augmentations are common solutions in treating bone defects of total knee revision. However, the stress shielding and poor osteointegration resulted from metal block application could not be neglected in bone defects restoration. In this study, a novel porous metal block was designed with topology optimization to improve biomechanical performance. The biomechanical difference of the topologically optimized block, solid Ti6Al4V block, and porous Ti6Al4V block in treating bone defects of total knee revision was compared by finite element analysis. The inhomogeneous femoral model was created according to the computed tomography data. Combined with porous structures, minimum compliance topology optimization subjected to the volume fraction constraint was utilized for the redesign of the metal block. The region of interest was defined as a 10 mm area of the distal femur beneath the contacting surface. The biomechanical performance of daily motions was investigated. The von Mises stress, the strain energy density of the region of interest, and the von Mises stress of metal blocks were recorded. The results were analyzed in SPSS. In terms of the region of interest, the maximum von Mises stress of the topological optimized group increased obviously, and its average stress was significantly higher than that of the other groups (p < 0.05). Moreover, the topologically optimized block group had the highest maximum strain energy density of the three groups, and the lowest maximum stress of block was also found in this group. In this study, the stress shielding reduction and stress transfer capability were found obviously improved through topology optimization. Therefore, the topological optimized porous block is recommended in treating bone defects of total knee revision. Meanwhile, this study also provided a novel approach for mechanical optimization in block designing.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisBiomechanical PhenomenaFemurHumansKnee JointMaleMetalsMiddle AgedMetalsFinite element analysisMetal block augmentationPorous designTopology optimizationTotal knee revision