Evidence map›Paper›PMID 36695976›Full record

ArticleJournal of experimental orthopaedics2023

Pivot shift intraoperative quantitative assessment using a smartphone accelerometer in ACL deficient knees.

Guillaume Soudé, Jean-Baptiste De Villeneuve Bargemon, Raghbir Khakha, Martine Pithioux, Jean-Noël Argenson, Matthieu Ollivier, Christophe Jacquet

Open access · goldAbstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.3field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

Guillaume SoudéAix-Marseille University, CNRS, ISM UMR 7287, 13288, cedex 09, Marseille, France.
Jean-Baptiste De Villeneuve BargemonDepartment of Orthopedic surgery and Traumatology St. Marguerite Hospital, Institute of movement and locomotion, 270 Boulevard Sainte Marguerite, 29 13274, Marseille, BP, France.
Raghbir KhakhaGuys and St Thomas Hospitals, London, UK.
Martine PithiouxAix-Marseille University, CNRS, ISM UMR 7287, 13288, cedex 09, Marseille, France.
Jean-Noël ArgensonAix-Marseille University, CNRS, ISM UMR 7287, 13288, cedex 09, Marseille, France.
Matthieu OllivierAix-Marseille University, CNRS, ISM UMR 7287, 13288, cedex 09, Marseille, France.
Christophe JacquetAix-Marseille University, CNRS, ISM UMR 7287, 13288, cedex 09, Marseille, France. christophe.jacquet09@gmail.com.
Centre National de la Recherche Scientifique · FRHôpital Sainte-Marguerite · FRAix-Marseille Université · FRSt Thomas' Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe Pivot Shift (PS) test is a complex clinical sign that assesses the internal rotation and anterior tibial translation, which occurs abnormally in ACL deficient-knees. Because of the high inter-observer variability, different devices have been designed to characterize this complex movement in quantitative variables. The objective of this pilot study is to validate the reproducibility of intraoperative quantitative assessment of the PS with a smartphone accelerometer.

methodsTwelve ACL-injured knees were included and compared with the contralateral uninjured side. The PS was measured by two independent observers utilizing a smartphone accelerometer and graded according to the IKDC classification. Measurements were taken preoperatively, intraoperatively and postoperatively. Intraoperative readings were taken during each stage of reconstruction or repair of meniscoligamentous lesions including meniscal lesions, ramp lesions, ACL reconstruction and lateral tenodesis. Reproducibility of the measurements were evaluated according to an intraclass correlation coefficient (ICC).

resultsThe intra-observer reliability was good for the first examiner and excellent for the second examiner, with the ICC 0.89 [0.67, 0.98] p < 0,001 and ICC 0.97 [0.91, 1.0] p < 0,001 respectively. The inter-observer reliability was excellent between the two observers with the ICC 0.99 [0.97, 1.0] p < 0,001. The mean tibial acceleration measured 3.45 m.s

conclusionThe smartphone accelerometer is a reproducible device to quantitatively assess the internal rotation and anterior tibial translation during ACL reconstruction surgery. The measurements are influenced by the different surgical steps. Other larger cohort studies are needed to evaluate the specific impact of each step of the ACL reconstruction and meniscal repair on this measurement. An external validation using other technologies are needed to validate the reliability of this device to assess the PS test. LEVEL OF EVIDENCE: Level IV, case series, pilot study.

Indexed as

Anterior cruciate ligament repairKnee laxityMeniscus injuryProtocol studyPS testTriaxial smartphone accelerometer

Identifiers

PMID36695976
PMCPMC9877253
OpenAlexW4317915305

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.