ArticleMagma (New York, N.Y.)2023
Rapid microscopic 3D-diffusion tensor imaging fiber-tracking of mouse brain in vivo by super resolution reconstruction: validation on MAP6-KO mouse model.
Article in Magma (New York, N.Y.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 2 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectExploring mouse brains by rapid 3D-Diffusion Tensor Imaging (3D-DTI) of high spatial resolution (HSR) is challenging in vivo. Here we use the super resolution reconstruction (SRR) postprocessing method to demonstrate its performance on Microtubule-Associated-Protein6 Knock-Out (MAP6-KO) mice. MATERIALS AND
methodsTwo spin-echo DTI were acquired (9.4T, CryoProbe RF-coil): (i)-multislice 2D-DTI, (echo-planar integrating reversed-gradient) acquired in vivo in the three orthogonal orientations (360 μm slice-thickness, 120 × 120 μm in-plane resolution, 56 min scan duration); used in SRR software to reconstruct SRR 3D-DTI with HSR in slice-plane (120 × 120 × 120 µm) and (ii)-microscopic 3D-DTI (µ-3D-DTI), (100 × 100 × 100 µm; 8 h 6 min) on fixed-brains ex vivo, that were removed after paramagnetic contrast-agent injection to accelerate scan acquisition using short repetition-times without NMR-signal sensitivity loss.
resultsWhite-matter defects, quantified from both 3D-DTI fiber-tracking were found very similar. Indeed, as expected the fornix and cerebral-peduncle volume losses were - 39% and - 35% in vivo (SRR 3D-DTI) versus - 34% and - 32% ex vivo (µ-3D-DTI), respectively (p<0.001). This finding is robust since the µ-3D-DTI feasibility on MAP6-KO ex vivo was already validated by fluorescent-microscopy of cleared brains. DISCUSSION: First performance of the SRR to generate rapid HSR 3D-DTI of mouse brains in vivo is demonstrated. The method is suitable in neurosciences for longitudinal studies to identify molecular and genetic abnormalities in mouse models that are of growing developments.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.