ArticleScientific reports2023
Feasibility of a multigroup Boltzmann-Fokker-Planck solution for electron beam dose calculations.
Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Review
- Extending deterministic transport capabilities for very-high and ultra-high energy electron beams.Scientific reports · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Legacy nuclear-reactor Boltzmann solvers start clinical deployment as an alternative to Monte Carlo (MC) codes and Fermi-Eyges semiemprical models in radiation oncology treatment planning. Today's certified clinical solvers are limited to photon beams. In this paper, ELECTR, a state-of-the-art multigroup electron cross sections generation module in NJOY is presented and validated against Lockwood's calorimetric measurements, EGS-nrc and GEANT-4 for 1-20 MeV unidirectional electron beams. The nuclear-reactor DRAGON-5 solver is upgraded to access the library and solve the Boltzmann-Fokker-Planck (BFP) equation. A variety of heterogeneous radiotherapy and radiosurgery phantom configurations were used for validation purpose. Case studies include a thorax benchmark, that of a typical breast Intra-Operative Radiotherapy and a high-heterogeneity patient-like benchmark. For all beams, [Formula: see text] of the water voxels satisfied the American Association of Physicists in Medicine accuracy criterion for a BFP-MC dose error below [Formula: see text]. At least, [Formula: see text] of adipose, muscle, bone, lung, tumor and breast voxels satisfied the [Formula: see text] criterion. The average BFP-MC relative error was about [Formula: see text] for all voxels, beams and materials combined. By irradiating homogeneous slabs from [Formula: see text] (hydrogen) to [Formula: see text] (einsteinium), we reported performance and defects of the CEPXS mode [US. Sandia National Lab., SAND-89-1685] in ELECTR for the entire periodic table. For all Lockwood's benchmarks, NJOY-DRAGON dose predictions are within the experimental data precision for [Formula: see text] of voxels.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.