Evidence map›Paper›PMID 36691891›Full record

ArticleRadiation protection dosimetry2023

RADIATION DOSE OF THE EYE LENS IN CT EXAMINATIONS OF THE BRAIN IN CLINICAL PRACTICE-THE EFFECT OF RADIOGRAPHER TRAINING TO OPTIMISE GANTRY TILT AND SCAN LENGTH.

Jeremias Tarkiainen, Miia Nadhum, Annele Heikkilä, Irina Rinta-Kiikka, Atte Joutsen

Open access · hybridAbstract read
In one paragraph

Article in Radiation protection dosimetry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
4.6field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Observational
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Jeremias TarkiainenFaculty of Medicine and Health Technology, Tampere University, Tampere, Finland.ORCID 0000-0002-5997-2184
Miia NadhumFaculty of Medicine and Health Technology, Tampere University, Tampere, Finland.
Annele HeikkiläFaculty of Medicine and Health Technology, Tampere University, Tampere, Finland.
Irina Rinta-KiikkaDepartment of Radiology, Medical Imaging Center, Pirkanmaa Hospital District, Tampere, Finland.
Atte JoutsenDepartment of Medical Physics, Medical Imaging Center, Pirkanmaa Hospital District, Tampere, Finland.ORCID 0000-0002-5870-4428
Tampere University · FIPirkanmaa Hospital District · FI

Funding

Tampere University Hospital
6 · The paper itself

Abstract

Lenses are always exposed to radiation in brain computed tomography (CT) scans. However, the lens dose can be reduced by excluding lens from scanning area by optimising gantry tilt and scan length. The object of this study is to retrospectively analyse if the optimisation by gantry tilt and scan length have been adequate in the CT scan of the brain, and to prospectively analyse the effect of radiographer training to the quality of the CT examinations. This study was conducted in two parts. In all, 329 brain CTs performed in the Tampere University Hospital from 2017 to 2019 were revised retrospectively. The prospective part included 51 brain CT studies conducted in October 2021. Dose to the eye of the lens was modelled using CT-Expo using zero-degree beam angle and scan lengths to expose the lens either to the primary or scattered radiation. Non-zero gantry tilt had been used in a large proportion of the CT examinations in the retrospective setting, 84.8%. However, the lenses were successfully excluded from the scan area in only 1.8% of the examinations. In the prospective part, the gantry tilt was used in 98% of the studies and the proportion of successful examinations rose from 1.8 to 11.8%. The lens dose decreased significantly when the eyes were excluded from the imaging area. The modelled lens dose in the large retrospective part was 25.9 mGy (17.8-49.2 mGy) when the eyes were included and 1.5 mGy (0.4-1.9 mGy) when the eyes were excluded. The lens dose was similar in the small prospective part. Despite the gantry tilt is widely used, unnecessary lens irradiation occurs extensively because of suboptimal gantry tilt and scan length. The training of radiographers reduces the radiation exposure to the lens by more optimal gantry tilt and scan length.

Indexed as

Lens, CrystallineTomography, X-Ray ComputedHumansProspective StudiesRadiation DosageRetrospective Studieseye lensGantry tiltlens irradiationscan length optimisationsupraorbitomeatal line

Identifiers

PMID36691891
PMCPMC10077499
OpenAlexW4317830860

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.