ArticlePlastic and reconstructive surgery. Global open2023
Minimally Required Personal Protective Equipment during Local Anesthesia Surgery in COVID-19: A Simulation Study.
Article in Plastic and reconstructive surgery. Global open, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In the era of the coronavirus disease 2019 (COVID-19) pandemic, surgeons and medical staff are often at a high risk of infection in the operating room, especially when the patient is spontaneously breathing. In this study, we examined the minimum requirements for personal protective equipment with double surgical masks to potentially reduce unnecessary waste of supplies. Methods: Two mannequins were each connected to a test lung machine simulating a surgeon and patient with spontaneous breathing. An aerosol generator containing severe acute respiratory syndrome coronavirus 2 virion particle substitutes was connected to the patient mannequin. The sampling points for the target molecules were set at different distances from the patient mannequin and sent for multiplex quantitative polymerase chain reaction analysis. Three clinical scenarios were designed, which differed in terms of the operating room pressure and whether a fabric curtain barrier was installed between the mannequins. Results: Analysis of the multiplex quantitative polymerase chain reaction results showed that the cycle threshold (Ct) value of the target molecule increased as the distance from the aerosol source increased. In the negative-pressure operating room, the Ct values were significantly increased at all sample points compared with the normal pressure room setting. The Ct value sampled at the surgeon mannequin wearing double face masks was significantly increased when a cloth curtain barrier was set up between the two mannequins. Conclusion: Double surgical masks provide elementary surgeon protection against COVID-19 in a negative pressure operating room, with a physical barrier in place between the surgeon and patient who is spontaneously breathing during local anesthesia or sedated surgery.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.