Evidence map›Paper›PMID 36691594›Full record

ArticleOphthalmology science2023

Automated Detection of Posterior Vitreous Detachment on OCT Using Computer Vision and Deep Learning Algorithms.

Alexa L Li, Moira Feng, Zixi Wang, Sally L Baxter, Lingling Huang, Justin Arnett, Dirk-Uwe G Bartsch, David E Kuo, Bharanidharan Radha Saseendrakumar, Joy Guo and 1 more

Abstract read
In one paragraph

Article in Ophthalmology science, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Vision transformers: The next frontier for deep learning-based ophthalmic image analysis.Saudi journal of ophthalmology : official journal of the Saudi Ophthalmological Society
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Alexa L LiViterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California at San Diego, La Jolla, California.
Moira FengJacobs School of Engineering, University of California San Diego, La Jolla, California.
Zixi WangJacobs School of Engineering, University of California San Diego, La Jolla, California.
Sally L BaxterViterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California at San Diego, La Jolla, California.
Lingling HuangViterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California at San Diego, La Jolla, California.
Justin ArnettViterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California at San Diego, La Jolla, California.
Dirk-Uwe G BartschViterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California at San Diego, La Jolla, California.
David E KuoViterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California at San Diego, La Jolla, California.
Bharanidharan Radha SaseendrakumarViterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California at San Diego, La Jolla, California.
Joy GuoViterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California at San Diego, La Jolla, California.
Eric NudlemanViterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California at San Diego, La Jolla, California.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To develop automated algorithms for the detection of posterior vitreous detachment (PVD) using OCT imaging. Design: Evaluation of a diagnostic test or technology. Subjects: Overall, 42 385 consecutive OCT images (865 volumetric OCT scans) obtained with Heidelberg Spectralis from 865 eyes from 464 patients at an academic retina clinic between October 2020 and December 2021 were retrospectively reviewed. Methods: We developed a customized computer vision algorithm based on image filtering and edge detection to detect the posterior vitreous cortex for the determination of PVD status. A second deep learning (DL) image classification model based on convolutional neural networks and ResNet-50 architecture was also trained to identify PVD status from OCT images. The training dataset consisted of 674 OCT volume scans (33 026 OCT images), while the validation testing set consisted of 73 OCT volume scans (3577 OCT images). Overall, 118 OCT volume scans (5782 OCT images) were used as a separate external testing dataset. Main Outcome Measures: Accuracy, sensitivity, specificity, F1-scores, and area under the receiver operator characteristic curves (AUROCs) were measured to assess the performance of the automated algorithms. Results: Both the customized computer vision algorithm and DL model results were largely in agreement with the PVD status labeled by trained graders. The DL approach achieved an accuracy of 90.7% and an F1-score of 0.932 with a sensitivity of 100% and a specificity of 74.5% for PVD detection from an OCT volume scan. The AUROC was 89% at the image level and 96% at the volume level for the DL model. The customized computer vision algorithm attained an accuracy of 89.5% and an F1-score of 0.912 with a sensitivity of 91.9% and a specificity of 86.1% on the same task. Conclusions: Both the computer vision algorithm and the DL model applied on OCT imaging enabled reliable detection of PVD status, demonstrating the potential for OCT-based automated PVD status classification to assist with vitreoretinal surgical planning. Financial Disclosures: Proprietary or commercial disclosure may be found after the references.

Indexed as

AI, artificial intelligenceAUROC, area under the receiver operator characteristic curveAutomated detectionCNN, convolutional neural networkDeep LearningDL, deep learningILM, internal limiting membraneOCTPosterior vitreous detachmentPVD, posterior vitreous detachmentViT, vision transformers

Identifiers

PMID36691594
PMCPMC9860346

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.