Evidence map›Paper›PMID 36690980›Full record

ArticleBMC ophthalmology2023

Polyester 5-0 suture for porous implant placement after retinoblastoma enucleation: analysis of 120 sockets.

Huijing Ye, Rongxin Chen, Wei Xiao, Xiufen Lian, Huasheng Yang

Open access · goldAbstract read
In one paragraph

Article in BMC ophthalmology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.6field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Huijing Ye *State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, 510060, China. yehuijing@qq.com.
Rongxin Chen *State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, 510060, China.
Wei XiaoState Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, 510060, China.
Xiufen LianState Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, 510060, China.
Huasheng YangState Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, 510060, China. yanghs64@126.com.
Sun Yat-sen University · CN

Funding

National Natural Science Foundation of China 81870689Scientific research project of Traditional Chinese Medicine Bureau of Guangdong Province 20211077Sun Yat-Sen University Clinical Research 5010 Program, China 2014014
6 · The paper itself

Abstract

backgroundTechniques used to suture the rectus muscle to the implant can influence the implant-related complications which is still a major problem following retinoblastoma enucleation. The goals of this work were to report the efficacy among patients with retinoblastoma who underwent enucleation followed by porous implant placement with the rectus muscles sutured with 5-0 polyester suture.

methodsThis was a retrospective study of consecutive patients with retinoblastoma who underwent primary enucleation and porous implant placement with the rectus muscles tagged and sutured to the implant with polyester 5-0 suture. All the patients were followed up for a minimum of 2 years. The main outcome measure was implant exposure. The secondary efficacy measures were other implant-related complications.

resultsBetween May 2016 and December 2018, a total of 120 patients (120 eyes) underwent primary enucleation and porous implant placement were included. Postoperatively, 10/120 (8.3%) eyes developed exposure or conjunctival granuloma. Exposure was the most common postoperative complication (7/10, 70.0%). There were no cases of implant extrusion, migration, or infection.

conclusionsPolyester 5-0 sutures are successful in patients with retinoblastoma who underwent enucleation followed by porous implant placement. Complications are minimal. Polyester 5-0 sutures were not associated with unacceptable complications in this pediatric population.

Indexed as

Orbital ImplantsRetinal NeoplasmsRetinoblastomaChildEye EnucleationHumansPolyestersPorosityPostoperative ComplicationsProsthesis ImplantationRetrospective StudiesSuturesPolyestersImplant exposureRetinoblastomaSutures

Identifiers

PMID36690980
PMCPMC9869537
OpenAlexW4317746162

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.