Evidence map›Paper›PMID 36689147›Full record

ArticleInternational journal of computer assisted radiology and surgery2023

Development of a remote-control system for catheterization capable of high-speed force feedback.

Rei Takagi, Keita Osada, Akihiko Hanafusa, Motoki Takagi, Shahrol Bin Mohamaddan, Kazuyuki Mitsui, Hidenobu Anzai

Open access · hybridFull text read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. A Master-Follower Teleoperation System for Robotic Catheterisation: Design, Characterisation and Tracking Control.The international journal of medical robotics + computer assisted surgery : MRCAS · 2025
    Article
  3. Development of a remote-control system for catheterization capable of high-speed force feedback.International journal of computer assisted radiology and surgery · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Rei TakagiDepartment of Bio-Science and Engineering, Shibaura Institute of Technology, 307 Fukasaku, Minuma-Ku, Saitama, 337-8570, Japan.
Keita OsadaDepartment of Bio-Science and Engineering, Shibaura Institute of Technology, 307 Fukasaku, Minuma-Ku, Saitama, 337-8570, Japan.
Akihiko HanafusaDepartment of Bio-Science and Engineering, Shibaura Institute of Technology, 307 Fukasaku, Minuma-Ku, Saitama, 337-8570, Japan. hanafusa@shibaura-it.ac.jp.ORCID http://orcid.org/0000-0002-1437-8202
Motoki TakagiDepartment of Bio-Science and Engineering, Shibaura Institute of Technology, 307 Fukasaku, Minuma-Ku, Saitama, 337-8570, Japan.
Shahrol Bin MohamaddanDepartment of Bio-Science and Engineering, Shibaura Institute of Technology, 307 Fukasaku, Minuma-Ku, Saitama, 337-8570, Japan.
Kazuyuki MitsuiDepartment of Advanced Machinery Engineering, Tokyo Denki University, Tokyo, Japan.
Hidenobu AnzaiFujikura Kasei Co., Tokyo, Japan.
Shibaura Institute of Technology · JPFujikura (Japan) · JPTokyo Denki University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThere is a growing interest in minimally invasive surgery as interventional radiology (IVR), which decreases the burden on a patient. However, occupational exposure is a problem because the treatment is performed using X-ray fluoroscopic images. This problem can be solved by the development of a teleoperation system, but rapid force presentation is important to perform safe surgery. The purpose of this study is to develop a new teleoperation system that can be controlled at a high speed and can provide feedback force sensation within 20 ms delay.

methodsA master-slave-type remote-control system for catheterization was developed. A compact and high-speed force feedback system is realized using a novel electro-attractive material (EAM) device by which the resistance force is generated by the magnitude of the voltage applied. The linear and rotational movement of master is transferred to the slave device by UDP communication with the LAN cable, and the same movement is performed by two motors. The collision force of catheter or guidewire, detected by the sensor inside the slave device, is also transmitted to the master device. Two voltage-based methods for EAM: the ON/OFF and linear control methods, were implemented.

resultsAfter the collision force is detected by the slave sensor, the voltage is applied to the EAM in the master device for an average of 10.33 ms and 15.64 ms by the ON/OFF and linear control methods, respectively. These delays are less than required 20 ms. The movement of the master was stopped by the resistance force of EAM, and that of the slave was also stopped accordingly.

conclusionA master-slave-type remote-control system for catheterization that is capable of high-speed force feedback was developed. With a low delay, the developed system achieved the requirements of 20 ms that was aimed for this study. Therefore, this system may facilitate the realization of IVR surgery that is safe for both doctors and patients.

Indexed as

RoboticsCatheterizationEquipment DesignFeedbackHumansUser-Computer InterfaceElectro-attractive material (EAM)Force feedbackInterventional radiology (IVR)Master–slave systemTeleoperation system

Identifiers

PMID36689147
PMCPMC10039843
OpenAlexW4317745739

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read6
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.