Evidence map›Paper›PMID 36688730›Full record

ArticleDento maxillo facial radiology2023

As low as diagnostically acceptable dose imaging in maxillofacial trauma: a reference quality approach.

Gerlig Widmann, Hannes Schönthaler, Alexander Tartarotti, Gerald Degenhart, Romed Hörmann, Gudrun Feuchtner, Reinhilde Jacobs, Ruben Pauwels

Abstract read
In one paragraph

Article in Dento maxillo facial radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Observational
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Gerlig WidmannDepartment of Radiology, Medical University of Innsbruck, Innsbruck, Austria.ORCID 0000-0002-7255-0672
Hannes SchönthalerDepartment of Radiology, Medical University of Innsbruck, Innsbruck, Austria.
Alexander TartarottiDepartment of Imaging and Pathology, OMFS-IMPATH Research Group, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.
Gerald DegenhartDepartment of Radiology, Medical University of Innsbruck, Innsbruck, Austria.
Romed HörmannDivision of Clinical and Functional Anatomy, Medical University of Innsbruck, Innsbruck, Austria.
Gudrun FeuchtnerDepartment of Radiology, Medical University of Innsbruck, Innsbruck, Austria.
Reinhilde JacobsDepartment of Imaging and Pathology, OMFS-IMPATH Research Group, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.
Ruben PauwelsDepartment of Imaging and Pathology, OMFS-IMPATH Research Group, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesAs-low-as-diagnostically-acceptable (ALADA) doses are substantially lower than current diagnostic reference levels. To improve dose management, a reference quality approach was tested in which phantom quality metrics of a clinical ALADA dose reference protocol were used to benchmark potential ALADA dose protocols for various scanner models.

methodsSpatial resolution, contrast resolution, contrast-to-noise ratio (CNR) and subjective noise and sharpness were evaluated for a clinical ALADA dose reference protocol at 80 kV and 40 mA (CTDIvol 2.66 mGy) and compared with test protocols of two CT scanners at 100 kV and 35 mA (3.08-3.44 mGy), 80 kV and 54-61 mA (2.65 mGy), 80 kV and 40 mA (1.73-1.92 mGy), and 80 kV and 21-23 mA (1.00-1.03 mGy) using different kernels, filtered backprojection and iterative reconstructions. The test protocols with the lowest dose showing quality metrics non-inferior to the reference protocol were verified in a cadaver study by determining the diagnostic accuracy of detection of maxillofacial fractures and CNR of the optical nerve and rectus inferior muscle.

results36 different image series were analysed in the phantom study. Based on the phantom quality metrics, potential ALADA dose protocols at 1.73-1.92 mGy were selected. Compared with the reference images, the selected protocols showed non-inferiority in the detection and classification of maxillofacial fractures and non-inferior CNR of orbital soft tissues in the cadaver study.

conclusionsReference quality metrics from clinical ALADA dose protocols may be used to guide selection of potential ALADA dose protocols of different CT scanners.

Indexed as

Maxillofacial InjuriesTomography, X-Ray ComputedCadaverHumansPhantoms, ImagingRadiation DosageRadiographic Image Interpretation, Computer-AssistedBone fracturesComparative studyDiagnostic ImagingFaceRadiation dose

Identifiers

PMID36688730
PMCPMC9944010

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.