Evidence map›Paper›PMID 36685290›Full record

ArticleJournal of mass spectrometry and advances in the clinical lab2023

Identification of a frit-related sample carryover in newborn screening by tandem mass spectrometry.

Kyunghun Kim, Howon Lee, Jeong Joong Lee, Kyoungho Cha, Nam Hyun Park, Young Keun Shin, Hyojin Chae, Eun-Jee Oh

Open access · goldAbstract read
In one paragraph

Article in Journal of mass spectrometry and advances in the clinical lab, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Kyunghun KimDepartment of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Howon LeeDepartment of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Jeong Joong LeeDepartment of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Kyoungho ChaDepartment of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Nam Hyun ParkBio-Medical Science Co., Ltd, Seoul, Republic of Korea.
Young Keun ShinWaters Korea Ltd, Seoul, Republic of Korea.
Hyojin ChaeDepartment of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Eun-Jee OhDepartment of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
The Catholic University of Korea Seoul St. Mary's Hospital · KRBio-Medical Science (South Korea) · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The need for high-throughput analysis of multiple analytes for inborn errors of metabolism in newborn screening (NBS) has led to the introduction of tandem mass spectrometry (MS/MS) into the NBS laboratory. In a flow-injection analysis (FIA), the predominant MS/MS method utilized for NBS, samples are introduced directly into the mass spectrometer without chromatographic separation. When a high-throughput FIA-based MS/MS method is implemented on newer generations of mass spectrometers with increased sensitivity, the risk of carryover and contamination increases. In the present study, we report the carryover of ornithine identified during the implementation of the NeoBase™ 2 (PerkinElmer) non-derivatized kits on the Xevo-TQD platform (Waters Corporation) and describe the source of the carryover, which was traced to the stainless-steel frit-type inline filter. Furthermore, a possible compound-dependent interaction with the stainless-steel frit is suggested based on the structure of ornithine and its effect on separation techniques. Investigation and mitigation of carryover can be a time and resource consuming process, and to this end, our report on identification of a stainless-steel frit as the source of delayed elution and carryover of ornithine should be recognized as a rare, albeit possible source of carryover in FIA-MS/MS methods adopted for NST.

Indexed as

CarryoverDBS, Dried blood spotESI, Electrospray ionizationFIA, Flow-injection analysisFlow injection analysisFTN, Flow through needleH, highHPLC, High performance liquid chromatographyIEM, Inborn errors of metabolismIPA, IsopropanolLC, Liquid chromatographyLLOQ, Lower limit of quantitationL, lowMS, Mass spectrometerMS/MS, Tandem mass spectrometryNBS, Newborn screeningNewborn screeningOrnithinePEEK, PolyetheretherketonepI, Isoelectric pointQC, Quality controlSM, Sample managerTandem mass spectrometryTIC, Total ion chromatogramUPLC, Ultra performance liquid chromatography

Identifiers

PMID36685290
PMCPMC9850200
OpenAlexW4313596574

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.