To Study the Impact of Different Optimization Methods on Intensity-Modulated Radiotherapy and Volumetric-Modulated Arc Therapy Plans for Hip Prosthesis Patients.
Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 5 citations in OpenAlex.
- Dosimetric assessment of conventional and advanced algorithms in clinical stereotactic radiotherapy.Precision radiation oncology · 2025Article
- The impact of metal implants on the dose and clinical outcome of radiotherapy (Review).Molecular and clinical oncology · 2024Review
- Evaluation of the Treatment Planning and Delivery for Hip Implant Cases on Tomotherapy.Journal of medical physicsArticle
- Retrospective Comparative Study on Dose Gradients and Peripheral Dose Management in Advanced Radiotherapy Systems.Journal of medical physicsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To study the impact of different optimization methods in dealing with metallic hip implant using intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) techniques. Materials and Methods: A cohort of 16 patients having metallic implants was selected for the study. Three sets of IMRT and VMAT plans were generated. Set 1 IMRT (IM_Base), VMAT (VM_Base) without any restrictions on beam entry and exit, set 2 (IM_ENT and VM_ENT) optimizer restricts the beam entry and set 3 (IM_EXT+ENT), neither entry nor exit doses were allowed toward the metallic implant. Results: There was no significant difference in target (D Conclusion: The best approach is to plan hip prosthesis cases with blocked entry of radiation beam for IMRT and VMAT. The VMAT plans had more volumetric coverage, fewer hotspots, and lesser heterogeneity.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.