Biomechanical study of femoral neck system for young patients with nonanatomically reduced femoral neck fractures: a finite element.

Zhirong Fan, Ping Chen, Xiubing Yu, Xing Li, Haitao Su, Haiyun Chen, Bing Yang, Ji Qi, Haizhou Wang

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. [Short-term effectiveness of robot-guided femoral neck system combined with cannulated compression screw fixation in treatment of femoral neck fracture in young and middle-aged patients].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024
    Article
  7. Article
  8. Article
  9. Article
  10. Positive buttress reduction in femoral neck fractures: a literature review.Journal of orthopaedic surgery and research · 2024
    Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Zhirong Fan *Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou University of Chinese Medicine, 510006, Guangzhou, China.
Ping Chen *Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou University of Chinese Medicine, 510006, Guangzhou, China.
Xiubing YuGuangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou University of Chinese Medicine, 510006, Guangzhou, China.
Xing LiGuangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou University of Chinese Medicine, 510006, Guangzhou, China.
Haitao SuGuangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou University of Chinese Medicine, 510006, Guangzhou, China.
Haiyun ChenGuangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou University of Chinese Medicine, 510006, Guangzhou, China.
Bing YangGuangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou University of Chinese Medicine, 510006, Guangzhou, China.
Ji QiGuangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou University of Chinese Medicine, 510006, Guangzhou, China.
Haizhou WangGuangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou University of Chinese Medicine, 510006, Guangzhou, China. szylngzk@gzucm.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA consensus regarding the optimal approach for treating femoral neck fractures is lacking. We aimed to investigate the biomechanical outcomes of Femoral Neck System (FNS) internal fixation components in the treatment of nonanatomically reduced femoral neck fractures.

methodWe constructed two types of femoral neck fractures of the Pauwels classification with angles of 30° and 50°, and three models of anatomic reduction, positive buttress reduction and negative buttress reduction were constructed. Subgroups of 1 to 4 mm were divided according to the distance of displacement in the positive buttress reduction and negative buttress reduction models. The von Mises stress and displacements of the femur and FNS internal fixation components were measured for each fracture group under 2100-N axial loads.

resultsWhen the Pauwels angle was 30°, the positive 1-mm and 2-mm models had lower FNS stress than the negative buttress model. The positive 3- and 4-mm models showed FNS stress similar to that of the negative buttress model. But the four positive buttress models had similar stresses on the femur as the negative buttress model. When the Pauwels angle was 50°, the four positive buttress models had higher FNS stress than the negative buttress model. Three positive buttress models (2 mm, 3 and 4 mm) resulted in lower stress of the femur than the negative buttress model, though the 1-mm model did not. When the Pauwels angle was 30°, the positive buttress model had a lower displacement of the FNS than the negative buttress model and a similar displacement of the femur with the negative buttress model. When the Pauwels angle was 50°, the positive buttress model had a higher displacement of the FNS and femur than the negative buttress model. Our study also showed that the von Mises stress and displacement of the internal fixation and the femur increased as the fracture angle increased.

conclusionFrom the perspective of biomechanics, when the Pauwels angle was 30°, positive buttress was more stable to negative buttress. However, when the Pauwels angle was 50°, this advantage weakens. In our opinion, the clinical efficacy of FNS internal fixation with positive buttress may be related to the fracture angle, neck-shaft angle and alignment in the lateral view. This result needs verification in further clinical studies.

Indexed as

Femoral Neck FracturesFemur NeckBiomechanical PhenomenaFinite Element AnalysisFracture Fixation, InternalHumansTreatment OutcomeFemoral neck fractureFemoral neck systemFinite element analysisFNSNegative buttressPositive buttress

Identifiers

PMID36681804
PMCPMC9862848

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390