ArticleBMC musculoskeletal disorders2023
Biomechanical study of femoral neck system for young patients with nonanatomically reduced femoral neck fractures: a finite element.
Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Femoral neck system versus cannulated screws combined with medial plate for femoral neck fractures in young and middle-aged patients: a prospective multicenter randomized controlled trial.Journal of orthopaedic surgery and research · 2025Trial
- Is DHS with Fibular Strut Graft Superior for the Fixation of Comminuted Femoral Neck Fractures (FNF)? A Comparative Analysis with New Implant Femoral Neck System.Indian journal of orthopaedics · 2025Article
- Femoral calcar double-supported screw fixation enhances biomechanical stability in Pauwels type III femoral neck fractures: a comparative biomechanical study.American journal of translational research · 2025Article
- Fracture classification and coronal plane position of bolt may affect the prognosis after femoral neck system (FNS) surgery for femoral neck fractures.BMC surgery · 2024Article
- Biomechanical effects of FNS on femoral neck fractures based on different reduction quality: finite element analysis.BMC musculoskeletal disorders · 2024Article
- [Short-term effectiveness of robot-guided femoral neck system combined with cannulated compression screw fixation in treatment of femoral neck fracture in young and middle-aged patients].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024Article
- Nonanatomical reduction of femoral neck fractures in young patients with different Pauwels classifications: a retrospective study and finite element analysis.BMC musculoskeletal disorders · 2024Article
- Evaluating three internal fixation techniques for Pauwels III femoral neck fractures via finite element analysis.Scientific reports · 2024Article
- A finite element analysis of a low-profile femoral neck system of screws in sleeves in a vertical femoral neck fracture model.BMC musculoskeletal disorders · 2024Article
- Positive buttress reduction in femoral neck fractures: a literature review.Journal of orthopaedic surgery and research · 2024Review
- Biomechanical investigation of positive reduction in the femoral neck fracture: a finite element analysis.Frontiers in bioengineering and biotechnology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundA consensus regarding the optimal approach for treating femoral neck fractures is lacking. We aimed to investigate the biomechanical outcomes of Femoral Neck System (FNS) internal fixation components in the treatment of nonanatomically reduced femoral neck fractures.
methodWe constructed two types of femoral neck fractures of the Pauwels classification with angles of 30° and 50°, and three models of anatomic reduction, positive buttress reduction and negative buttress reduction were constructed. Subgroups of 1 to 4 mm were divided according to the distance of displacement in the positive buttress reduction and negative buttress reduction models. The von Mises stress and displacements of the femur and FNS internal fixation components were measured for each fracture group under 2100-N axial loads.
resultsWhen the Pauwels angle was 30°, the positive 1-mm and 2-mm models had lower FNS stress than the negative buttress model. The positive 3- and 4-mm models showed FNS stress similar to that of the negative buttress model. But the four positive buttress models had similar stresses on the femur as the negative buttress model. When the Pauwels angle was 50°, the four positive buttress models had higher FNS stress than the negative buttress model. Three positive buttress models (2 mm, 3 and 4 mm) resulted in lower stress of the femur than the negative buttress model, though the 1-mm model did not. When the Pauwels angle was 30°, the positive buttress model had a lower displacement of the FNS than the negative buttress model and a similar displacement of the femur with the negative buttress model. When the Pauwels angle was 50°, the positive buttress model had a higher displacement of the FNS and femur than the negative buttress model. Our study also showed that the von Mises stress and displacement of the internal fixation and the femur increased as the fracture angle increased.
conclusionFrom the perspective of biomechanics, when the Pauwels angle was 30°, positive buttress was more stable to negative buttress. However, when the Pauwels angle was 50°, this advantage weakens. In our opinion, the clinical efficacy of FNS internal fixation with positive buttress may be related to the fracture angle, neck-shaft angle and alignment in the lateral view. This result needs verification in further clinical studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials